Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0446 # 04 Y:2014 | 04 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,214 | $40 | Not Implemented |
BD0446 # 05 Y:2014 | 05 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,189 | $1,040 | Not Implemented |
BD0446 # 06 Y:2014 | 06 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,450 | $1,420 | Not Implemented |
BD0446 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,065 | $20 | Not Implemented |
BD0446 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $510 | $900 | Not Implemented |
BD0446 # 09 Y:2014 | 09 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $366 | $800 | Not Implemented |
CO0686 # 01 Y:2014 | 01 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,160 | $8,890 | Not Implemented |
CO0686 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,170 | $6,690 | Not Implemented |
CO0686 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,690 | $0 | Implemented |
CO0686 # 04 Y:2014 | 04 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $6,330 | $27,820 | Implemented |
CO0686 # 05 Y:2014 | 05 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,080 | $1,500 | Implemented |
CO0686 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,120 | $4,630 | Not Implemented |
MZ0144 # 01 Y:2014 | 01 | 2014 | COVER OPEN TANKS | $6,406 | $5,250 | Not Implemented |
MZ0144 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $9,563 | $12,000 | Implemented |
MZ0144 # 03 Y:2014 | 03 | 2014 | INSULATE BARE EQUIPMENT | $824 | $900 | Implemented |
MZ0144 # 04 Y:2014 | 04 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $13,431 | $4,400 | Not Implemented |
MZ0144 # 05 Y:2014 | 05 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,120 | $7,400 | Implemented |
MZ0144 # 06 Y:2014 | 06 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,940 | $5,500 | Not Implemented |
MZ0144 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,683 | $15,640 | Implemented |
TT0129 # 01 Y:2014 | 01 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $107,559 | $235,000 | Not Implemented |
TT0129 # 02 Y:2014 | 02 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,620 | $2,025 | Not Implemented |
TT0129 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,827 | $3,000 | Not Implemented |
TT0129 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,882 | $3,000 | Implemented |
MI0261 # 01 Y:2014 | 01 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $48,959 | $119,260 | Not Implemented |
MI0261 # 02 Y:2014 | 02 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $13,152 | $5,847 | Implemented |