Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,529
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0685 # 08 Y:2000 | 08 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $14,950 | $4,740 | Not Implemented |
GT0659 # 01 Y:1999 | 01 | 1999 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $88,180 | $220,000 | n/a |
GT0659 # 02 Y:1999 | 02 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $3,484 | $0 | n/a |
GT0659 # 03 Y:1999 | 03 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $37,040 | $10,000 | n/a |
GT0659 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,123 | $400 | n/a |
GT0659 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,706 | $22,711 | n/a |
GT0659 # 06 Y:1999 | 06 | 1999 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $45,013 | $120,000 | n/a |
GT0684 # 01 Y:2000 | 01 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,160 | $0 | Not Implemented |
GT0684 # 02 Y:2000 | 02 | 2000 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $1,325 | $0 | Not Implemented |
GT0684 # 03 Y:2000 | 03 | 2000 | USE POWER DURING OFF-PEAK PERIODS | $1,975 | $0 | Not Implemented |
GT0684 # 04 Y:2000 | 04 | 2000 | CLOSE OUTDOOR AIR DAMPERS DURING WARM-UP / COOL-DOWN PERIODS | $1,632 | $2,450 | Not Implemented |
GT0684 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,200 | $19,600 | Not Implemented |
GT0678 # 01 Y:1999 | 01 | 1999 | METER WASTE WATER | $4,925 | $900 | Implemented |
GT0678 # 02 Y:1999 | 02 | 1999 | REDUCE EXCESSIVE BOILER BLOWDOWN | $920 | $900 | Not Implemented |
GT0678 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,880 | $3,500 | Not Implemented |
GT0678 # 04 Y:1999 | 04 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,400 | $0 | Not Implemented |
GT0678 # 05 Y:1999 | 05 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,447 | $21,000 | Not Implemented |
GT0678 # 06 Y:1999 | 06 | 1999 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $35,980 | $0 | Implemented |
GT0678 # 07 Y:1999 | 07 | 1999 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $44,185 | $120,000 | Not Implemented |
GT0678 # 08 Y:1999 | 08 | 1999 | COMBINE UTILITY METERS | $7,560 | $7,500 | Not Implemented |
GT0683 # 01 Y:2000 | 01 | 2000 | COMBINE UTILITY METERS | $14,609 | $0 | Not Implemented |
GT0683 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $180,287 | $358,400 | Not Implemented |
GT0683 # 03 Y:2000 | 03 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,689 | $2,080 | Not Implemented |
GT0683 # 04 Y:2000 | 04 | 2000 | INSTALL SYSTEM TO COLLECT SCRAP | $59,893 | $12,000 | Not Implemented |
GT0683 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,590 | $108,696 | Not Implemented |