Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0621 # 05 Y:2001 | 05 | 2001 | IMPROVE SPACE COMFORT CONDITIONING | $47,308 | $16,792 | Not Implemented |
OK0619 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $792 | $310 | Implemented |
OK0619 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,585 | $18,400 | Not Implemented |
OK0619 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $816 | $878 | Not Implemented |
OK0619 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,184 | $200 | Implemented |
OK0619 # 05 Y:2001 | 05 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,191 | $1,423 | Not Implemented |
OK0619 # 06 Y:2001 | 06 | 2001 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $38,340 | $12,500 | Not Implemented |
OK0619 # 07 Y:2001 | 07 | 2001 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $68,500 | $15,000 | Implemented |
OK0619 # 08 Y:2001 | 08 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,200 | $1,326 | Implemented |
OK0619 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,082 | $3,936 | Not Implemented |
OK0619 # 10 Y:2001 | 10 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,577 | $3,000 | Implemented |
OK0619 # 11 Y:2001 | 11 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,523 | $10,275 | Implemented |
OK0619 # 12 Y:2001 | 12 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $29,565 | $10,000 | Not Implemented |
OK0619 # 13 Y:2001 | 13 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $877 | $0 | Implemented |
OK0623 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,052 | $6,513 | Implemented |
OK0623 # 02 Y:2001 | 02 | 2001 | USE OPTIMUM THICKNESS INSULATION | $8,776 | $550 | Implemented |
OK0623 # 03 Y:2001 | 03 | 2001 | INSTALL SET-BACK TIMERS | $6,800 | $1,035 | Not Implemented |
OK0623 # 04 Y:2001 | 04 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $1,256 | $200 | Implemented |
OK0623 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $614 | $245 | Not Implemented |
OK0623 # 06 Y:2001 | 06 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $8,620 | $21,240 | Implemented |
OK0623 # 07 Y:2001 | 07 | 2001 | IMPROVE SPACE COMFORT CONDITIONING | $25,723 | $9,332 | Not Implemented |
OK0623 # 08 Y:2001 | 08 | 2001 | INSTALL SET-BACK TIMERS | $4,652 | $4,500 | Implemented |
OK0623 # 09 Y:2001 | 09 | 2001 | AUTOMATE FINISHING PROCESS | $41,030 | $150,000 | Not Implemented |
OK0623 # 10 Y:2001 | 10 | 2001 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $99,840 | $57,120 | Not Implemented |
OK0623 # 11 Y:2001 | 11 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $4,160 | $4,300 | Not Implemented |