Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,289
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0258 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,508 | $50 | Implemented |
NC0258 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $763 | $1,147 | Not Implemented |
NC0258 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,881 | $600 | Implemented |
NC0257 # 01 Y:2003 | 01 | 2003 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $169,269 | $200,000 | Not Implemented |
NC0257 # 02 Y:2003 | 02 | 2003 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $24,665 | $10,000 | Not Implemented |
NC0257 # 03 Y:2003 | 03 | 2003 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $42,749 | $55,000 | Not Implemented |
NC0257 # 04 Y:2003 | 04 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $335,124 | $425,000 | n/a |
NC0257 # 05 Y:2003 | 05 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $8,216 | $8,241 | Implemented |
NC0257 # 06 Y:2003 | 06 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,771 | $2,118 | Implemented |
NC0257 # 07 Y:2003 | 07 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,455 | $500 | Implemented |
NC0257 # 08 Y:2003 | 08 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,407 | $840 | Implemented |
NC0257 # 09 Y:2003 | 09 | 2003 | USE PHOTOCELL CONTROLS | $1,346 | $1,540 | Implemented |
NC0259 # 01 Y:2003 | 01 | 2003 | INSULATE BARE EQUIPMENT | $7,357 | $1,650 | Implemented |
NC0259 # 02 Y:2003 | 02 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $3,711 | $5,940 | Implemented |
NC0259 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $6,070 | $0 | Not Implemented |
NC0259 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,905 | $50 | Implemented |
NC0259 # 05 Y:2003 | 05 | 2003 | USE PHOTOCELL CONTROLS | $4,513 | $2,750 | Not Implemented |
NC0259 # 06 Y:2003 | 06 | 2003 | ADD AREA LIGHTING SWITCHES | $3,306 | $1,200 | Not Implemented |
NC0259 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $887 | $862 | Implemented |
NC0259 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,879 | $1,740 | Implemented |
NC0259 # 09 Y:2003 | 09 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,286 | $10,000 | Not Implemented |
NC0259 # 10 Y:2003 | 10 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,785 | $12,240 | Implemented |
NC0259 # 11 Y:2003 | 11 | 2003 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $3,651 | $38,000 | Not Implemented |
NC0253 # 01 Y:2003 | 01 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $81,956 | $105,000 | n/a |
NC0253 # 02 Y:2003 | 02 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,127 | $1,000 | Not Implemented |