Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

60

matching recommendations
Reset
NAICS 331 Primary Metal Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0397 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,897 $420 Implemented
SD0397 # 04 Y:2007 04 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,700 $23,250 Not Implemented
SD0397 # 03 Y:2007 03 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,149 $18,100 Not Implemented
SD0397 # 02 Y:2007 02 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $52,328 $44,175 Not Implemented
SD0397 # 01 Y:2007 01 2007 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $51,686 $51,240 Not Implemented
SD0397 # 09 Y:2007 09 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,243 $3,825 Not Implemented
AS0385 # 02 Y:2004 02 2004 ELIMINATE/REDUCE AN OPERATION $151,757 $37,000 Not Implemented
AS0385 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,304 $10,000 Not Implemented
AS0385 # 03 Y:2004 03 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $59,563 $24,322 Not Implemented
AS0385 # 04 Y:2004 04 2004 REPROCESS SPENT OILS ON SITE FOR RE-USE $42,444 $17,685 Not Implemented
AS0385 # 05 Y:2004 05 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $719 $506 Not Implemented
AS0385 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $383 $30 Not Implemented
AS0385 # 07 Y:2004 07 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,939 $60 Not Implemented
AS0385 # 08 Y:2004 08 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $339 $150 Not Implemented
AS0383 # 09 Y:2004 09 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $406 $367 Not Implemented
AS0383 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $842 $200 Not Implemented
AS0383 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $21,498 $120 Not Implemented
AS0383 # 03 Y:2004 03 2004 $16,320 $40,000 Not Implemented
AS0383 # 04 Y:2004 04 2004 INSTALL OCCUPANCY SENSORS $2,878 $1,350 Not Implemented
AS0383 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,064 $12,003 Not Implemented
AS0383 # 06 Y:2004 06 2004 COVER OPEN TANKS $4,988 $6,000 Not Implemented
AS0383 # 07 Y:2004 07 2004 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $244 $600 Not Implemented
AS0383 # 08 Y:2004 08 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,942 $600 Not Implemented
AS0383 # 10 Y:2004 10 2004 $577,735 $9,735 Not Implemented
AS0345 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,950 $30 Implemented