Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
39
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0347 # 04 Y:2004 | 04 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,700 | $18,500 | Not Implemented |
SD0347 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,911 | $450 | Implemented |
SD0347 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,552 | $0 | Implemented |
SD0347 # 05 Y:2004 | 05 | 2004 | $128,000 | $145,000 | Not Implemented | |
SD0347 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,721 | $21,387 | Not Implemented |
LM0076 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,513 | $880 | Implemented |
LM0076 # 05 Y:2004 | 05 | 2004 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $6,736 | $2,500 | Implemented |
LM0076 # 06 Y:2004 | 06 | 2004 | $1,766 | $1,500 | Not Implemented | |
LM0076 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,953 | $3,825 | Not Implemented |
LM0076 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $528 | $25 | Implemented |
LM0076 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $255 | $281 | Implemented |
LM0076 # 02 Y:2004 | 02 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,952 | $1,300 | Implemented |
SD0332 # 01 Y:2004 | 01 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $164,104 | $609,600 | Not Implemented |
SD0332 # 05 Y:2004 | 05 | 2004 | INSTALL SKYLIGHTS | $3,460 | $7,015 | Not Implemented |
SD0332 # 04 Y:2004 | 04 | 2004 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,750 | $6,000 | Not Implemented |
SD0332 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,765 | $900 | Implemented |
SD0332 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,679 | $475 | Implemented |
SD0331 # 05 Y:2004 | 05 | 2004 | $108,200 | $110,000 | Implemented | |
SD0331 # 01 Y:2004 | 01 | 2004 | USE PHOTOCELL CONTROLS | $4,358 | $410 | Not Implemented |
SD0331 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $643 | $453 | Not Implemented |
SD0331 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $204 | $0 | Not Implemented |
SD0331 # 04 Y:2004 | 04 | 2004 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,220 | $5,000 | Implemented |
LM0069 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $417 | $15 | Implemented |
LM0069 # 13 Y:2004 | 13 | 2004 | $16,000 | $5,000 | Not Implemented | |
LM0069 # 12 Y:2004 | 12 | 2004 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $170,219 | $0 | Implemented |