Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 336 | Nonferrous Foundries (castings) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0260 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,624 | $8,000 | Not Implemented |
SD0260 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,341 | $1,326 | Not Implemented |
SD0260 # 04 Y:2000 | 04 | 2000 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,824 | $1,500 | Not Implemented |
SD0260 # 05 Y:2000 | 05 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $1,678 | $400 | Not Implemented |
SD0260 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,528 | $13,000 | Not Implemented |
SD0260 # 07 Y:2000 | 07 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $45,000 | $8,800 | Not Implemented |
SD0260 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,292 | $11,000 | Not Implemented |
SD0260 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,150 | $30,000 | Not Implemented |
SD0253 # 06 Y:2000 | 06 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,732 | $5,400 | Not Implemented |
SD0253 # 07 Y:2000 | 07 | 2000 | $22,500 | $15,000 | Not Implemented | |
SD0253 # 05 Y:2000 | 05 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,622 | $7,000 | Not Implemented |
SD0253 # 04 Y:2000 | 04 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,561 | $12,000 | Not Implemented |
SD0253 # 03 Y:2000 | 03 | 2000 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $20,080 | $25,000 | Not Implemented |
SD0253 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,706 | $15,000 | Not Implemented |
SD0253 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $108,760 | $68,000 | Not Implemented |
SD0255 # 07 Y:2000 | 07 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $903 | $40 | Not Implemented |
SD0255 # 06 Y:2000 | 06 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,869 | $1,950 | Not Implemented |
SD0255 # 09 Y:2000 | 09 | 2000 | $25,800 | $23,000 | Not Implemented | |
SD0255 # 08 Y:2000 | 08 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $487 | $25 | Not Implemented |
SD0255 # 05 Y:2000 | 05 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,611 | $350 | Implemented |
SD0255 # 04 Y:2000 | 04 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,459 | $0 | Implemented |
SD0255 # 01 Y:2000 | 01 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $124,864 | $87,000 | Not Implemented |
SD0255 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,967 | $40,000 | Implemented |
SD0255 # 03 Y:2000 | 03 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,615 | $7,500 | Implemented |
SD0254 # 04 Y:2000 | 04 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,675 | $0 | Implemented |