Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

197

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0189 # 03 Y:2000 03 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $807 $1,711 Implemented
SF0189 # 04 Y:2000 04 2000 INSTALL OCCUPANCY SENSORS $1,491 $2,520 Implemented
SF0189 # 05 Y:2000 05 2000 $8,916 $14,480 Implemented
SF0189 # 06 Y:2000 06 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,102 $36,670 Implemented
SF0189 # 07 Y:2000 07 2000 MINIMIZE WATER USAGE $23,452 $125,000 Implemented
SD0243 # 05 Y:2000 05 2000 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,209 $7,872 Implemented
SD0243 # 06 Y:2000 06 2000 INSULATE BARE EQUIPMENT $4,293 $9,936 Implemented
SD0243 # 09 Y:2000 09 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,098 $500 Implemented
SD0242 # 01 Y:2000 01 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,399 $1,960 Implemented
SD0242 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,903 $0 Implemented
SD0242 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,533 $8,500 Implemented
SD0241 # 01 Y:2000 01 2000 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,946 $24,320 Implemented
SD0241 # 03 Y:2000 03 2000 REDUCE EXCESSIVE BOILER BLOWDOWN $2,831 $6,150 Implemented
SD0241 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,802 $0 Implemented
SD0241 # 06 Y:2000 06 2000 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $274 $0 Implemented
SF0187 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,271 $0 Implemented
SF0187 # 02 Y:2000 02 2000 SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON $1,393 $0 Implemented
SF0187 # 03 Y:2000 03 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $3,336 $1,446 Implemented
SF0187 # 04 Y:2000 04 2000 TURN OFF EQUIPMENT WHEN NOT IN USE $360 $370 Implemented
SF0187 # 05 Y:2000 05 2000 INSTALL OCCUPANCY SENSORS $1,236 $2,040 Implemented
SF0187 # 06 Y:2000 06 2000 INSTALL OCCUPANCY SENSORS $851 $2,250 Implemented
SF0187 # 07 Y:2000 07 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,569 $4,392 Implemented
SF0187 # 08 Y:2000 08 2000 INSTALL SPECTRAL REFLECTORS / DELAMP $7,099 $32,250 Implemented
SF0187 # 09 Y:2000 09 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,849 $10,470 Implemented
SF0187 # 10 Y:2000 10 2000 RECOVER AND REUSE WASTE MATERIAL $1,085 $0 Implemented