Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0475 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $38,801 | $8,131 | Not Implemented |
SD0475 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $72,583 | $20,000 | Not Implemented |
SD0475 # 01 Y:2013 | 01 | 2013 | REDUCE SCRAP PRODUCTION | $478,006 | $153,240 | Not Implemented |
SD0475 # 02 Y:2013 | 02 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $74,589 | $105,000 | Not Implemented |
SD0469 # 03 Y:2013 | 03 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,384 | $50,200 | Not Implemented |
SD0473 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $13,184 | $13,290 | Implemented |
SD0473 # 02 Y:2013 | 02 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,120 | $8,000 | Not Implemented |
SD0473 # 03 Y:2013 | 03 | 2013 | REDUCE EXCESS STEAM BLEEDING | $8,903 | $24,743 | Implemented |
SD0473 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,042 | $500 | Not Implemented |
SD0473 # 05 Y:2013 | 05 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,946 | $9,300 | Not Implemented |
SD0473 # 06 Y:2013 | 06 | 2013 | USE PHOTOCELL CONTROLS | $4,729 | $6,475 | Not Implemented |
SD0473 # 07 Y:2013 | 07 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,448 | $11,250 | Implemented |
SD0473 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,017 | $500 | Implemented |
SD0473 # 09 Y:2013 | 09 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $1,067 | $400 | Implemented |
SD0473 # 10 Y:2013 | 10 | 2013 | INSTALL OCCUPANCY SENSORS | $1,066 | $2,700 | Not Implemented |
SD0473 # 11 Y:2013 | 11 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $789 | $1,300 | Implemented |
SD0469 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,250 | $200 | Implemented |
SD0469 # 07 Y:2013 | 07 | 2013 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,825 | $1,500 | Not Implemented |
SF0436 # 06 Y:2013 | 06 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $608 | $2,400 | Not Implemented |
SF0436 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,275 | $12,405 | Not Implemented |
SF0436 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $864 | $2,751 | Not Implemented |
SF0436 # 01 Y:2013 | 01 | 2013 | COVER OPEN TANKS | $6,314 | $150 | Not Implemented |
SF0436 # 02 Y:2013 | 02 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $438 | $0 | Implemented |
SF0436 # 03 Y:2013 | 03 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $2,488 | $3,272 | Not Implemented |
SD0469 # 01 Y:2013 | 01 | 2013 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $37,421 | $53,250 | Implemented |