IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0404 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $365 $498 Implemented
CO0404 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,420 $280 Implemented
CO0404 # 05 Y:1997 05 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $200 $0 Implemented
CO0404 # 01 Y:1997 01 1997 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,800 $5,000 Implemented
CO0404 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $210 $440 Implemented
CO0400 # 04 Y:1997 04 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $630 $0 Implemented
CO0400 # 06 Y:1997 06 1997 $35,100 $1,800 Implemented
CO0400 # 03 Y:1997 03 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,220 $420 Implemented
CO0400 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,292 $1,356 Implemented
CO0399 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,240 $600 Implemented
CO0399 # 06 Y:1997 06 1997 $45,100 $13,100 Implemented
CO0399 # 05 Y:1997 05 1997 USE A RAG RECYCLE SERVICE $480 $0 Implemented
CO0399 # 04 Y:1997 04 1997 IMPROVE COMBUSTION CONTROL CAPABILITY $320 $750 Implemented
CO0396 # 01 Y:1997 01 1997 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,020 $1,690 Implemented
CO0396 # 06 Y:1997 06 1997 $12,600 $3,600 Implemented
CO0396 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $100 $0 Implemented
CO0396 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $691 $1,050 Implemented
CO0396 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $270 $1,000 Implemented
CO0396 # 04 Y:1997 04 1997 UPGRADE OBSOLETE EQUIPMENT $180 $540 Implemented
CO0395 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $920 $-3,940 Implemented
CO0395 # 02 Y:1997 02 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $630 $930 Implemented
CO0393 # 08 Y:1997 08 1997 $113,220 $25,000 Implemented
CO0393 # 06 Y:1997 06 1997 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES $9,120 $10,000 Implemented
CO0393 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $358 $403 Implemented
CO0393 # 01 Y:1997 01 1997 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $4,000 $1,170 Implemented