Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0685 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $898 | $1,280 | Not Implemented |
MA0685 # 04 Y:2011 | 04 | 2011 | REDUCE VENTILATION AIR | $2,713 | $6,300 | Implemented |
MA0685 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $3,520 | $9,425 | Implemented |
MA0685 # 02 Y:2011 | 02 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,714 | $0 | Not Implemented |
MA0685 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,634 | $7,050 | Not Implemented |
MA0681 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $152 | $80 | Not Implemented |
MA0681 # 04 Y:2011 | 04 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $768 | $300 | Not Implemented |
MA0681 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,163 | $1,265 | Implemented |
MA0681 # 02 Y:2011 | 02 | 2011 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,294 | $1,220 | Not Implemented |
MA0681 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $6,162 | $9,261 | Implemented |
MA0678 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,343 | $0 | Implemented |
MA0678 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,833 | $8,590 | Not Implemented |
MA0678 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,819 | $26,495 | Not Implemented |
MA0678 # 04 Y:2011 | 04 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,186 | $0 | Implemented |
MA0678 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,204 | $5,760 | Implemented |
MA0678 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,383 | $88,700 | Implemented |
MA0676 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $593 | $1,250 | Implemented |
MA0676 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $1,721 | $2,750 | Implemented |
MA0676 # 03 Y:2011 | 03 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,019 | $500 | Not Implemented |
MA0676 # 02 Y:2011 | 02 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $24,027 | $4,000 | Not Implemented |
MA0676 # 01 Y:2011 | 01 | 2011 | OPTIMIZE PLANT POWER FACTOR | $204,367 | $98,845 | Implemented |
MA0668 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,378 | $1,800 | Implemented |
MA0668 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $986 | $950 | Implemented |
MA0668 # 06 Y:2011 | 06 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,802 | $7,000 | Not Implemented |
MA0668 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,755 | $200 | Not Implemented |