Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

177

matching recommendations
Reset
SIC 3841 Surgical And Medical Instruments
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0405 # 04 Y:2022 04 2022 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $9,041 $580 Not Implemented
MI0405 # 03 Y:2022 03 2022 USE SOLAR HEAT TO HEAT WATER $22,766 $62,612 Not Implemented
MI0405 # 02 Y:2022 02 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,714 $39,398 Implemented
MI0405 # 01 Y:2022 01 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $51,243 $208,000 Implemented
MI0337 # 08 Y:2018 08 2018 INSTALL OCCUPANCY SENSORS $14,515 $19,215 Implemented
MI0337 # 07 Y:2018 07 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,813 $2,030 Implemented
MI0337 # 06 Y:2018 06 2018 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $21,780 $78,320 Not Implemented
MI0337 # 05 Y:2018 05 2018 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $24,458 $31,600 Not Implemented
MI0337 # 04 Y:2018 04 2018 INSULATE BARE EQUIPMENT $26,104 $3,000 Implemented
MI0337 # 03 Y:2018 03 2018 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $31,197 $11,846 Not Implemented
MI0337 # 11 Y:2018 11 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,571 $6,578 Implemented
MI0337 # 10 Y:2018 10 2018 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,724 $7,314 Implemented
MI0337 # 09 Y:2018 09 2018 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,557 $2,528 Not Implemented
MI0337 # 02 Y:2018 02 2018 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $41,184 $480 Implemented
MI0337 # 01 Y:2018 01 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $45,349 $76,979 Implemented
MI0333 # 04 Y:2018 04 2018 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $7,399 $15,000 Implemented
MI0333 # 08 Y:2018 08 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $328 $826 Implemented
MI0333 # 07 Y:2018 07 2018 INSULATE BARE EQUIPMENT $2,191 $2,240 Implemented
MI0333 # 06 Y:2018 06 2018 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $4,911 $80 Implemented
MI0333 # 02 Y:2018 02 2018 AIR CONDITION ONLY SPACE NECESSARY $17,320 $2,724 Implemented
MI0333 # 05 Y:2018 05 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,026 $13,843 Implemented
MI0333 # 01 Y:2018 01 2018 PURCHASE EQUIPMENT INSTEAD OF LEASING $304,263 $795,000 Not Implemented
MI0333 # 03 Y:2018 03 2018 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $10,427 $320 Implemented
UF0516 # 04 Y:2018 04 2018 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM $200,000 $100,000 Not Implemented
UF0516 # 07 Y:2018 07 2018 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $23,725 $10,695 Not Implemented