IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

222

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0138 # 08 Y:1996 08 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $730 $0 Implemented
IA0143 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,183 $640 Implemented
IA0143 # 02 Y:1996 02 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,401 $1,128 Not Implemented
IA0143 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,672 $463 Implemented
IA0143 # 04 Y:1996 04 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $282 $25 Implemented
IA0143 # 05 Y:1996 05 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $27,825 $54,500 Implemented
IA0143 # 06 Y:1996 06 1996 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $5,446 $16,125 Not Implemented
IA0142 # 01 Y:1996 01 1996 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,323 $0 Not Implemented
IA0142 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,297 $63 Implemented
IA0142 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $350 $262 Implemented
IA0142 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $900 $1,362 Implemented
IA0142 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $346 $444 Implemented
IA0142 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $466 $92 Not Implemented
IA0142 # 07 Y:1996 07 1996 ELIMINATE/REDUCE AN OPERATION $653 $574 Not Implemented
IA0141 # 01 Y:1996 01 1996 USE RADIANT HEATER FOR SPOT HEATING $9,887 $1,427 Implemented
IA0141 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,108 $5,087 Not Implemented
IA0141 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $145 $1,366 Not Implemented
IA0141 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $102 $296 Implemented
IA0141 # 05 Y:1996 05 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,104 $239 Not Implemented
IA0141 # 06 Y:1996 06 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $862 $25 Implemented
IA0141 # 07 Y:1996 07 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $365 $150 Implemented
IA0141 # 08 Y:1996 08 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $341 $190 Implemented
IA0141 # 09 Y:1996 09 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,350 $5,000 Not Implemented
IA0141 # 10 Y:1996 10 1996 BURN WASTE OIL FOR HEAT $4,051 $12,500 Not Implemented
IA0141 # 11 Y:1996 11 1996 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $1,896 $2,755 Implemented