IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

324

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0091 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $783 $600 Implemented
BD0091 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,261 $400 Implemented
BD0091 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,875 $2,077 Implemented
BD0091 # 04 Y:1997 04 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,496 $1,920 Not Implemented
BD0091 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,396 $8,110 Implemented
BD0091 # 02 Y:1997 02 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $37,336 $500 Not Implemented
BD0091 # 01 Y:1997 01 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $38,324 $24,791 Implemented
WI0304 # 04 Y:1997 04 1997 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,297 $17,000 Not Implemented
WI0304 # 03 Y:1997 03 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,517 $500 Implemented
WI0304 # 02 Y:1997 02 1997 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,925 $10,000 Implemented
WI0304 # 01 Y:1997 01 1997 $27,000 $90,000 Not Implemented
WI0304 # 05 Y:1997 05 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,088 $2,144 Implemented
WI0304 # 06 Y:1997 06 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $600 $0 Implemented
BD0090 # 10 Y:1997 10 1997 $12,408 $480 Implemented
BD0090 # 01 Y:1997 01 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $33,305 $30,062 Implemented
BD0090 # 02 Y:1997 02 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $8,088 $17,646 Implemented
BD0090 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,924 $13,880 Not Implemented
BD0090 # 04 Y:1997 04 1997 RECOVER WASTE HEAT FROM EQUIPMENT $4,231 $950 Implemented
BD0090 # 05 Y:1997 05 1997 INSTALL OCCUPANCY SENSORS $3,769 $2,250 Implemented
BD0090 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,069 $2,035 Implemented
BD0090 # 08 Y:1997 08 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $31,686 $29,850 Implemented
BD0090 # 09 Y:1997 09 1997 USE A RAG RECYCLE SERVICE $3,953 $0 Implemented
BD0090 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,289 $0 Not Implemented
BD0089 # 01 Y:1997 01 1997 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $3,860 $5,500 Not Implemented
BD0089 # 02 Y:1997 02 1997 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $3,615 $1,250 Not Implemented