IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

456

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0063 # 07 Y:2003 07 2003 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $7,351 $24,365 Not Implemented
IC0062 # 01 Y:2003 01 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,452 $6,197 Not Implemented
IC0062 # 02 Y:2003 02 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,779 $14,546 Implemented
IC0062 # 03 Y:2003 03 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,105 $0 Implemented
IC0062 # 04 Y:2003 04 2003 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $8,560 $5,280 Implemented
IC0062 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $45,681 $10,200 Implemented
IC0062 # 06 Y:2003 06 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $20,526 $21,542 Implemented
IC0062 # 07 Y:2003 07 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $32,470 $28,470 Implemented
IC0062 # 08 Y:2003 08 2003 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $75,511 $20,000 Implemented
IC0062 # 09 Y:2003 09 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $33,052 $130,000 Not Implemented
BD0237 # 01 Y:2003 01 2003 USE RADIANT HEATER FOR SPOT HEATING $32,297 $56,000 Not Implemented
BD0237 # 02 Y:2003 02 2003 RECOVER WASTE HEAT FROM EQUIPMENT $8,921 $5,000 Not Implemented
BD0237 # 03 Y:2003 03 2003 USE SYNTHETIC LUBRICANT $4,857 $2,000 Not Implemented
BD0237 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,331 $0 Not Implemented
BD0237 # 05 Y:2003 05 2003 INSTALL OCCUPANCY SENSORS $1,365 $1,275 Not Implemented
BD0237 # 06 Y:2003 06 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $62,620 $10,000 Not Implemented
BD0237 # 07 Y:2003 07 2003 $39,936 $45,000 Not Implemented
BD0237 # 08 Y:2003 08 2003 $16,965 $7,000 Not Implemented
BD0237 # 09 Y:2003 09 2003 $12,480 $25,000 Not Implemented
BD0237 # 10 Y:2003 10 2003 $2,199 $0 Not Implemented
BD0236 # 01 Y:2003 01 2003 USE RADIANT HEATER FOR SPOT HEATING $20,989 $23,000 Not Implemented
BD0236 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,247 $900 Implemented
BD0236 # 03 Y:2003 03 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,511 $19,250 Implemented
BD0236 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,728 $200 Implemented
BD0236 # 05 Y:2003 05 2003 INSTALL OCCUPANCY SENSORS $3,143 $2,325 Implemented