Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
226
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0339 # 03 Y:1991 | 03 | 1991 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,071 | $0 | Implemented |
KU0339 # 04 Y:1991 | 04 | 1991 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $1,066 | $525 | Implemented |
KU0339 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $577 | $350 | Implemented |
KU0339 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $119 | Implemented |
KU0339 # 07 Y:1991 | 07 | 1991 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $415 | $0 | Implemented |
KU0339 # 08 Y:1991 | 08 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $144 | $0 | Implemented |
OK0311 # 01 Y:1990 | 01 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,239 | $2,150 | Implemented |
OK0311 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,549 | $750 | Implemented |
OK0311 # 04 Y:1990 | 04 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $578 | $190 | Implemented |
OK0311 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,396 | $0 | Implemented |
OK0311 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,494 | $975 | Implemented |
KU0254 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,185 | $2,000 | Implemented |
KU0254 # 03 Y:1988 | 03 | 1988 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $1,539 | $0 | Implemented |
KU0254 # 05 Y:1988 | 05 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $347 | $0 | Implemented |
KU0254 # 07 Y:1988 | 07 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,741 | $1,680 | Implemented |
KU0254 # 08 Y:1988 | 08 | 1988 | IMPROVE LUBRICATION PRACTICES | $159 | $0 | Implemented |
KU0255 # 02 Y:1988 | 02 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $646 | $0 | Implemented |
KU0255 # 03 Y:1988 | 03 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $107 | $40 | Implemented |
KU0255 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $213 | $100 | Implemented |
KU0255 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $154 | $0 | Implemented |
KU0242 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,183 | $6,000 | Implemented |
KU0242 # 02 Y:1988 | 02 | 1988 | REDESIGN PROCESS | $4,705 | $2,080 | Implemented |
KU0242 # 04 Y:1988 | 04 | 1988 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,965 | $3,600 | Implemented |
KU0242 # 06 Y:1988 | 06 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $1,519 | $1,800 | Implemented |
KU0242 # 07 Y:1988 | 07 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,236 | $1,500 | Implemented |