IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

176

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0259 # 08 Y:2004 08 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,205 $825 Implemented
UM0259 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $1,893 $68 Implemented
UM0259 # 10 Y:2004 10 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,765 $200 Implemented
UM0259 # 11 Y:2004 11 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,700 $1,100 Implemented
UM0258 # 01 Y:2004 01 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $29,426 $500 Not Implemented
UM0258 # 02 Y:2004 02 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,300 $15,300 Not Implemented
UM0258 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,545 $1,275 Not Implemented
UM0258 # 04 Y:2004 04 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,828 $900 Not Implemented
UM0258 # 05 Y:2004 05 2004 INSTALL OCCUPANCY SENSORS $4,117 $7,220 Not Implemented
UM0258 # 06 Y:2004 06 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,963 $2,000 Not Implemented
UM0258 # 07 Y:2004 07 2004 INSTALL OCCUPANCY SENSORS $2,720 $5,925 Not Implemented
UM0258 # 08 Y:2004 08 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,480 $500 Not Implemented
UM0257 # 01 Y:2004 01 2004 USE RADIANT HEATER FOR SPOT HEATING $10,326 $10,958 Implemented
UM0257 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,305 $9,817 Not Implemented
UM0257 # 03 Y:2004 03 2004 UPGRADE CONTROLS ON COMPRESSORS $2,448 $300 Implemented
UM0257 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,370 $300 Implemented
UM0257 # 05 Y:2004 05 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $737 $200 Implemented
UM0256 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,404 $385 Not Implemented
UM0256 # 02 Y:2004 02 2004 REDUCE VENTILATION AIR $11,361 $500 Not Implemented
UM0256 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $10,111 $5,310 Not Implemented
UM0256 # 04 Y:2004 04 2004 REVISE SMOKE CLEANUP FROM OPERATIONS $9,084 $4,000 Not Implemented
UM0256 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,652 $12,043 Not Implemented
UM0256 # 06 Y:2004 06 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,461 $1,000 Not Implemented
UM0255 # 01 Y:2004 01 2004 INSULATE BARE EQUIPMENT $10,323 $6,486 Implemented
UM0255 # 02 Y:2004 02 2004 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $6,279 $2,497 Implemented