Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
62
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0316 # 04 Y:2006 | 04 | 2006 | INSTALL OCCUPANCY SENSORS | $1,033 | $675 | Implemented |
BD0316 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $679 | $2,102 | Implemented |
BD0316 # 03 Y:2006 | 03 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $13,153 | $8,363 | Implemented |
BD0316 # 02 Y:2006 | 02 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $4,724 | $1,200 | Implemented |
BD0316 # 01 Y:2006 | 01 | 2006 | USE SYNTHETIC LUBRICANT | $7,871 | $800 | Not Implemented |
IA0389 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $394 | $344 | Not Implemented |
IA0389 # 09 Y:2006 | 09 | 2006 | UPGRADE OBSOLETE EQUIPMENT | $17,486 | $87,000 | Not Implemented |
IA0389 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $848 | $1,836 | Not Implemented |
IA0389 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $667 | $77 | Not Implemented |
IA0389 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $493 | $305 | Not Implemented |
IA0389 # 08 Y:2006 | 08 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $24,825 | $2,100 | Not Implemented |
IA0389 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,671 | $4,008 | Not Implemented |
IA0389 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,332 | $322 | Not Implemented |
IA0389 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $376 | $42 | Not Implemented |
BD0313 # 04 Y:2006 | 04 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $13,938 | $0 | Implemented |
BD0313 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,516 | $0 | Not Implemented |
BD0313 # 01 Y:2006 | 01 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $180,015 | $152 | Implemented |
BD0313 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,038 | $10,039 | Implemented |
BD0313 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,780 | $800 | Implemented |
BD0313 # 03 Y:2006 | 03 | 2006 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $162,249 | $310,000 | Not Implemented |
BD0313 # 02 Y:2006 | 02 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,962 | $5,000 | Implemented |
BD0313 # 09 Y:2006 | 09 | 2006 | INSTALL OCCUPANCY SENSORS | $3,815 | $1,275 | Implemented |
BD0313 # 05 Y:2006 | 05 | 2006 | INSTALL TURBULATORS | $2,094 | $1,500 | Implemented |
IA0388 # 08 Y:2006 | 08 | 2006 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $47,693 | $45,600 | Implemented |
IA0388 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $2,587 | $3,234 | Implemented |