Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

82

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0346 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,314 $12,874 Implemented
MS0332 # 06 Y:2008 06 2008 USE OPTIMUM THICKNESS INSULATION $143 $108 Implemented
MS0332 # 05 Y:2008 05 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $14,696 $6,360 Implemented
MS0332 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,591 $401 Implemented
MS0332 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,875 $65,823 Implemented
MS0332 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $358,713 $96,000 Not Implemented
MS0332 # 01 Y:2008 01 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $771,322 $1,000 Implemented
MS0271 # 01 Y:2005 01 2005 USE OPTIMUM THICKNESS INSULATION $46,503 $3,038 Not Implemented
MS0271 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $790 $1,539 Not Implemented
MS0271 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN WATER LINES AND VALVES $888 $250 Not Implemented
MS0271 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,569 $3,249 Not Implemented
MS0271 # 02 Y:2005 02 2005 USE RADIANT HEATER FOR SPOT HEATING $1,726 $3,000 Not Implemented
MS0219 # 05 Y:2002 05 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $23,617 $1,500 Implemented
MS0219 # 02 Y:2002 02 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $425,529 $1,452,000 Not Implemented
MS0219 # 08 Y:2002 08 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,971 $696 Implemented
MS0219 # 09 Y:2002 09 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $18,200 $0 Not Implemented
MS0219 # 01 Y:2002 01 2002 PREHEAT COMBUSTION AIR WITH WASTE HEAT $529,152 $198,480 Not Implemented
MS0219 # 07 Y:2002 07 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,779 $1,113 Implemented
MS0219 # 03 Y:2002 03 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $67,886 $1,950 Implemented
MS0219 # 06 Y:2002 06 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $20,902 $97 Implemented
MS0219 # 04 Y:2002 04 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $44,270 $30,411 Not Implemented
MS0187 # 04 Y:2001 04 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,329 $729 Implemented
MS0187 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $234 $128 Implemented
MS0187 # 02 Y:2001 02 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $8,020 $100 Implemented
MS0187 # 01 Y:2001 01 2001 INSTALL TIMERS AND/OR THERMOSTATS $2,288 $473 Not Implemented