IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

590

matching recommendations
Reset
NAICS 333 Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0922 # 08 Y:2015 08 2015 RECOVER WASTE HEAT FROM EQUIPMENT $7,944 $1,500 Not Implemented
UD0922 # 09 Y:2015 09 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,813 $1,000 Not Implemented
UD0922 # 10 Y:2015 10 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $39,230 $67,300 Not Implemented
UD0922 # 11 Y:2015 11 2015 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $10,020 $0 Not Implemented
WV0503 # 01 Y:2015 01 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,355 $27,692 Not Implemented
WV0503 # 02 Y:2015 02 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,444 $22,500 Not Implemented
WV0503 # 03 Y:2015 03 2015 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,630 $5,700 Not Implemented
WV0503 # 04 Y:2015 04 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,899 $500 Implemented
WV0503 # 05 Y:2015 05 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,831 $374 Implemented
WV0503 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,499 $3,530 Implemented
WV0503 # 07 Y:2015 07 2015 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $915 $1,000 Implemented
WV0503 # 08 Y:2015 08 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $407 $448 Implemented
WV0503 # 09 Y:2015 09 2015 DEVELOP A REPAIR/REPLACE POLICY $283 $630 Implemented
WV0503 # 10 Y:2015 10 2015 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $272 $1,250 Not Implemented
UD0900 # 01 Y:2014 01 2014 REDUCE VENTILATION AIR $27,790 $9,213 Implemented
UD0900 # 02 Y:2014 02 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $14,091 $200 Not Implemented
UD0900 # 03 Y:2014 03 2014 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $540 $1,500 Implemented
UD0900 # 04 Y:2014 04 2014 INSTALL OCCUPANCY SENSORS $698 $170 Not Implemented
UD0900 # 05 Y:2014 05 2014 INSTALL OCCUPANCY SENSORS $583 $210 Not Implemented
UD0900 # 06 Y:2014 06 2014 INSTALL OCCUPANCY SENSORS $119 $20 Not Implemented
UD0900 # 07 Y:2014 07 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $566 $0 Implemented
UD0900 # 08 Y:2014 08 2014 RECOVER WASTE HEAT FROM EQUIPMENT $565 $2,500 Implemented
UD0900 # 09 Y:2014 09 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $332 $0 Not Implemented
WV0484 # 01 Y:2014 01 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,596 $58,450 Not Implemented
WV0484 # 02 Y:2014 02 2014 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $24,659 $51,000 Not Implemented