IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

211

matching recommendations
Reset
SIC 3469 Metal Stampings, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0482 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,329 $7,021 Not Implemented
UD0482 # 05 Y:1996 05 1996 UPGRADE CONTROLS ON COMPRESSORS $12,397 $500 Not Implemented
UD0482 # 06 Y:1996 06 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,360 $310 Not Implemented
WV0056 # 01 Y:1995 01 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,069 $7,326 Not Implemented
WV0056 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,678 $250 Implemented
WV0056 # 03 Y:1995 03 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,010 $800 Not Implemented
WV0056 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,481 $1,482 Implemented
WV0056 # 05 Y:1995 05 1995 USE SYNTHETIC LUBRICANT $2,144 $0 Implemented
WV0056 # 06 Y:1995 06 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,014 $800 Not Implemented
WV0056 # 07 Y:1995 07 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,331 $2,659 Not Implemented
WV0056 # 08 Y:1995 08 1995 CONVERT TO AQUEOUS CLEANING SYSTEM $30,701 $60,000 Not Implemented
WV0056 # 09 Y:1995 09 1995 USE EVAPORATION TO CONCENTRATE MATERIAL $66,455 $6,100 Not Implemented
WV0056 # 10 Y:1995 10 1995 USE LESS WASTEFUL PACKAGING $9,764 $0 Not Implemented
WV0056 # 11 Y:1995 11 1995 USE LESS WASTEFUL PACKAGING $5,696 $0 Not Implemented
UD0444 # 01 Y:1994 01 1994 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $15,232 $15,000 Not Implemented
UD0444 # 02 Y:1994 02 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,000 $0 Implemented
UD0444 # 03 Y:1994 03 1994 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,048 $8,000 Implemented
UD0444 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,528 $4,550 Not Implemented
UD0444 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,137 $8,000 Not Implemented
UD0299 # 01 Y:1989 01 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,009 $0 Not Implemented
UD0299 # 02 Y:1989 02 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $900 $0 Implemented
UD0299 # 03 Y:1989 03 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,667 $750 Implemented
UD0299 # 04 Y:1989 04 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $889 $750 Implemented
UD0299 # 05 Y:1989 05 1989 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $1,588 $1,720 Implemented
UD0260 # 01 Y:1988 01 1988 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $4,647 $500 Implemented