Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0801 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,877 | $16,721 | Implemented |
UD0801 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,100 | $14,833 | Implemented |
UD0801 # 07 Y:2009 | 07 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $993 | $45,000 | Implemented |
UD0779 # 12 Y:2008 | 12 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,658 | $1,000 | Implemented |
UD0779 # 11 Y:2008 | 11 | 2008 | $4,322 | $0 | Implemented | |
UD0779 # 08 Y:2008 | 08 | 2008 | INSULATE BARE EQUIPMENT | $8,895 | $412 | Implemented |
UD0779 # 06 Y:2008 | 06 | 2008 | IMPROVE COMBUSTION CONTROL CAPABILITY | $75,942 | $100,000 | Implemented |
UD0779 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,503 | $3,318 | Implemented |
UD0779 # 04 Y:2008 | 04 | 2008 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $13,555 | $500 | Implemented |
UD0779 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $17,736 | $65,000 | Implemented |
UD0779 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $95,648 | $1,000 | Implemented |
UD0779 # 14 Y:2008 | 14 | 2008 | COVER OPEN TANKS | $537 | $360 | Implemented |
UD0779 # 13 Y:2008 | 13 | 2008 | INSULATE BARE EQUIPMENT | $1,228 | $100 | Implemented |
UD0712 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,715 | $60 | Implemented |
UD0712 # 02 Y:2005 | 02 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $8,635 | $1,000 | Implemented |
UD0712 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,839 | $839 | Implemented |
UD0712 # 07 Y:2005 | 07 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,166 | $525 | Implemented |
UD0712 # 11 Y:2005 | 11 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $259 | $1,000 | Implemented |
UD0695 # 13 Y:2004 | 13 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $397 | $756 | Implemented |
UD0695 # 11 Y:2004 | 11 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $784 | $0 | Implemented |
UD0695 # 10 Y:2004 | 10 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,110 | $0 | Implemented |
UD0695 # 08 Y:2004 | 08 | 2004 | USE MINIMUM SAFE OVEN VENTILATION | $2,564 | $0 | Implemented |
UD0695 # 15 Y:2004 | 15 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $339 | $0 | Implemented |
UD0695 # 09 Y:2004 | 09 | 2004 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,331 | $175 | Implemented |
UD0695 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM TEMPERATURE | $7,076 | $9 | Implemented |