Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
NAICS 311 Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0713 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $26,495 $85,051 Implemented
OK0713 # 03 Y:2005 03 2005 USE COMPRESSOR AIR FILTERS $5,346 $35 Implemented
OK0713 # 04 Y:2005 04 2005 $48,000 $35 Implemented
OK0713 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,796 $139,341 Not Implemented
OK0713 # 06 Y:2005 06 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,489 $3,283 Not Implemented
OK0713 # 07 Y:2005 07 2005 INSTALL OCCUPANCY SENSORS $561 $975 Not Implemented
OK0706 # 01 Y:2005 01 2005 USE DEMAND CONTROLLER OR LOAD SHEDDER $10,579 $1,500 Implemented
OK0706 # 02 Y:2005 02 2005 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $6,672 $13,451 Implemented
OK0706 # 03 Y:2005 03 2005 INSTALL SET-BACK TIMERS $4,084 $1,468 Not Implemented
OK0706 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,296 $2,239 Not Implemented
OK0706 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,610 $10,437 Not Implemented
OK0706 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $1,308 $802 Not Implemented
OK0706 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $821 $605 Not Implemented
OK0704 # 01 Y:2005 01 2005 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $7,257 $5,175 Not Implemented
OK0704 # 02 Y:2005 02 2005 OPERATE BOILERS ON HIGH FIRE SETTING $4,358 $1,436 Not Implemented
OK0704 # 03 Y:2005 03 2005 INSTALL OCCUPANCY SENSORS $820 $688 Not Implemented
OK0704 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,912 $8,734 Not Implemented
OK0704 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,011 $2,257 Not Implemented
OK0704 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,769 $11,310 Not Implemented
OK0704 # 07 Y:2005 07 2005 $8,000 $0 Not Implemented
OK0704 # 08 Y:2005 08 2005 INSTALL SET-BACK TIMERS $1,663 $20 Not Implemented
OK0704 # 09 Y:2005 09 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,463 $13,554 Not Implemented
OK0704 # 10 Y:2005 10 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $165 $1,153 Not Implemented
OK0700 # 01 Y:2005 01 2005 RECOVER WASTE HEAT FROM EQUIPMENT $78,457 $36,299 Not Implemented
OK0700 # 02 Y:2005 02 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $77,748 $3,000 Not Implemented