Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0709 # 11 Y:2005 11 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $159 $1,000 Not Implemented
OK0709 # 12 Y:2005 12 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $696 $4,181 Not Implemented
OK0694 # 01 Y:2004 01 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,045,517 $1,029,484 Not Implemented
OK0694 # 02 Y:2004 02 2004 BURN A LESS EXPENSIVE GRADE OF FUEL $60,059 $691 Not Implemented
OK0694 # 03 Y:2004 03 2004 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $9,026 $9,344 Not Implemented
OK0694 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $65,085 $407,420 Not Implemented
OK0694 # 05 Y:2004 05 2004 INSULATE BARE EQUIPMENT $2,247 $2,094 Implemented
OK0694 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,157 $2,968 Implemented
OK0648 # 01 Y:2002 01 2002 USE OPTIMUM THICKNESS INSULATION $12,108 $2,317 Implemented
OK0648 # 02 Y:2002 02 2002 PREHEAT COMBUSTION AIR WITH WASTE HEAT $38,422 $70,536 Not Implemented
OK0648 # 03 Y:2002 03 2002 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,590 $4,344 Not Implemented
OK0648 # 04 Y:2002 04 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,975 $4,500 Implemented
OK0648 # 05 Y:2002 05 2002 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $6,955 $22,000 Not Implemented
OK0648 # 06 Y:2002 06 2002 $59,232 $12,200 n/a
OK0648 # 07 Y:2002 07 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,683 $240 Implemented
OK0648 # 08 Y:2002 08 2002 INSTALL OCCUPANCY SENSORS $94 $288 Not Implemented
OK0648 # 09 Y:2002 09 2002 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $169,242 $37,910 n/a
OK0648 # 10 Y:2002 10 2002 COVER OPEN TANKS $1,983 $752 Not Implemented
OK0648 # 11 Y:2002 11 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $1,458 $702 Not Implemented
OK0633 # 08 Y:2002 08 2002 USE RADIANT HEATER FOR SPOT HEATING $5,822 $11,440 Not Implemented
OK0633 # 02 Y:2002 02 2002 INSTALL OCCUPANCY SENSORS $351 $720 Not Implemented
OK0633 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $766 $35,173 Implemented
OK0633 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,451 $2,995 Implemented
OK0633 # 09 Y:2002 09 2002 INSTALL SET-BACK TIMERS $6,660 $3,570 Implemented
OK0633 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,287 $552 Implemented