Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0569 # 11 Y:1999 11 1999 INSTALL SET-BACK TIMERS $895 $420 Not Implemented
OK0558 # 01 Y:1998 01 1998 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $43,625 $44,730 Not Implemented
OK0558 # 02 Y:1998 02 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,594 $0 Implemented
OK0558 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $4,561 $3,300 Not Implemented
OK0558 # 04 Y:1998 04 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $149,760 $280,000 Implemented
OK0558 # 05 Y:1998 05 1998 COVER INK CONTAINERS WHEN NOT IN USE $49,090 $5,700 Implemented
OK0531 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $21,470 $0 Not Implemented
OK0531 # 02 Y:1997 02 1997 DISCONNECT BALLASTS $1,079 $500 Implemented
OK0531 # 03 Y:1997 03 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $631 $1,870 Not Implemented
OK0531 # 04 Y:1997 04 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $8,000 $0 Implemented
OK0531 # 05 Y:1997 05 1997 $27,300 $0 Not Implemented
OK0531 # 06 Y:1997 06 1997 $27,300 $150,000 Not Implemented
OK0490 # 01 Y:1996 01 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,884 $9,000 Implemented
OK0490 # 02 Y:1996 02 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $29,136 $12,600 Implemented
OK0490 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $952 $4,125 Implemented
OK0490 # 04 Y:1996 04 1996 METER WASTE WATER $678 $1,800 Not Implemented
OK0490 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $20 $50 Implemented
OK0479 # 01 Y:1995 01 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $31,839 $70,726 Not Implemented
OK0479 # 02 Y:1995 02 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $26,671 $25,000 Not Implemented
OK0479 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,121 $2,948 Implemented
OK0479 # 04 Y:1995 04 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,868 $3,950 Implemented
OK0479 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $1,266 $528 Implemented
OK0479 # 06 Y:1995 06 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $19,078 $11,000 Implemented
OK0479 # 07 Y:1995 07 1995 REDUCE SCRAP PRODUCTION $25,650 $0 Implemented
OK0482 # 01 Y:1995 01 1995 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $106,541 $79,290 Not Implemented