Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0385 # 03 Y:2000 | 03 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $7,231 | $600 | Implemented |
OR0385 # 06 Y:2000 | 06 | 2000 | OPTIMIZE PLANT POWER FACTOR | $670 | $1,900 | Not Implemented |
OR0385 # 07 Y:2000 | 07 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,638 | $10,431 | Implemented |
OR0385 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,380 | $0 | Implemented |
OR0385 # 01 Y:2000 | 01 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $10,600 | $58,000 | Not Implemented |
OR0385 # 02 Y:2000 | 02 | 2000 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $9,076 | $12,220 | Not Implemented |
OR0385 # 04 Y:2000 | 04 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,053 | $0 | Not Implemented |
OR0384 # 03 Y:2000 | 03 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $6,605 | $13,210 | Not Implemented |
OR0384 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $543 | $500 | Implemented |
OR0384 # 04 Y:2000 | 04 | 2000 | OPTIMIZE PLANT POWER FACTOR | $3,240 | $9,000 | Implemented |
OR0384 # 01 Y:2000 | 01 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $138,600 | $385,000 | Not Implemented |
OR0384 # 06 Y:2000 | 06 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,764 | $24,310 | Implemented |
OR0384 # 05 Y:2000 | 05 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,316 | $0 | Not Implemented |
OR0382 # 05 Y:2000 | 05 | 2000 | OPTIMIZE PLANT POWER FACTOR | $2,241 | $6,400 | Not Implemented |
OR0382 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,194 | $2,979 | Not Implemented |
OR0382 # 06 Y:2000 | 06 | 2000 | ELIMINATE A BY-PRODUCT | $68,235 | $2,000 | Implemented |
OR0382 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,208 | $26,491 | Implemented |
OR0382 # 04 Y:2000 | 04 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,050 | $4,653 | Not Implemented |
OR0382 # 01 Y:2000 | 01 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $26,817 | $900 | Implemented |
OR0381 # 06 Y:2000 | 06 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,970 | $40,500 | Not Implemented |
OR0381 # 02 Y:2000 | 02 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $699 | $300 | Implemented |
OR0381 # 01 Y:2000 | 01 | 2000 | IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM | $27,260 | $0 | Implemented |
OR0381 # 05 Y:2000 | 05 | 2000 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,096 | $390 | Implemented |
OR0381 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,850 | $8,600 | Implemented |
OR0381 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $540 | $345 | Not Implemented |