Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0274 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,705 | $2,885 | Not Implemented |
NC0274 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,021 | $1,000 | Implemented |
NC0274 # 04 Y:2003 | 04 | 2003 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $9,743 | $36,000 | Not Implemented |
NC0274 # 03 Y:2003 | 03 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,209 | $200 | Implemented |
NC0274 # 02 Y:2003 | 02 | 2003 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $36,152 | $81,000 | Not Implemented |
NC0274 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $18,125 | $77,500 | Not Implemented |
GT0768 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,376 | $0 | n/a |
GT0768 # 01 Y:2003 | 01 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,075 | $15,000 | n/a |
GT0768 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $42,648 | $0 | n/a |
GT0768 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $13,900 | $2,400 | n/a |
GT0768 # 05 Y:2003 | 05 | 2003 | COMBINE UTILITY METERS | $16,340 | $0 | n/a |
GT0768 # 06 Y:2003 | 06 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,160 | $0 | n/a |
GT0768 # 07 Y:2003 | 07 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $14,590 | $4,725 | n/a |
NC0256 # 05 Y:2003 | 05 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,851 | $30,000 | Not Implemented |
NC0256 # 10 Y:2003 | 10 | 2003 | MODIFY CURRENT INCENTIVE PROGRAM | $190,000 | $14,000 | Not Implemented |
NC0256 # 09 Y:2003 | 09 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $60,400 | $20,000 | Implemented |
NC0256 # 08 Y:2003 | 08 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,260 | $28,000 | Implemented |
NC0256 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $123 | $200 | Implemented |
NC0256 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $2,112 | $4,375 | Implemented |
NC0256 # 04 Y:2003 | 04 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,417 | $12,587 | Not Implemented |
NC0256 # 03 Y:2003 | 03 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,507 | $500 | Implemented |
NC0256 # 02 Y:2003 | 02 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $21,031 | $45,000 | Not Implemented |
NC0256 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $174,891 | $550,000 | Not Implemented |
NC0255 # 01 Y:2003 | 01 | 2003 | MAINTAIN CLEAN CONDITIONS BEFORE PAINTING | $300,000 | $150,000 | Not Implemented |
NC0255 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $668 | $120 | Not Implemented |