Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
242
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0501 # 04 Y:2013 | 04 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $21,685 | $33,000 | Implemented |
NC0501 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,920 | $100 | Implemented |
NC0501 # 02 Y:2013 | 02 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $35,397 | $25,000 | Implemented |
NC0501 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $68,635 | $375 | Not Implemented |
NC0468 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $785 | $900 | Not Implemented |
NC0468 # 04 Y:2012 | 04 | 2012 | INSTALL COMMON HEADER ON COMPRESSORS | $16,574 | $8,026 | Not Implemented |
NC0468 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $464 | $2,021 | Not Implemented |
NC0468 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $867 | $1,668 | Not Implemented |
NC0468 # 07 Y:2012 | 07 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $715 | Not Implemented |
NC0468 # 02 Y:2012 | 02 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,026 | $18,000 | Implemented |
NC0468 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $128 | $301 | Not Implemented |
NC0468 # 09 Y:2012 | 09 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,973 | $2,136 | Not Implemented |
NC0468 # 10 Y:2012 | 10 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,293 | $4,125 | Not Implemented |
NC0468 # 11 Y:2012 | 11 | 2012 | INSTALL OCCUPANCY SENSORS | $2,082 | $2,100 | Implemented |
NC0468 # 12 Y:2012 | 12 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $34,749 | $7,000 | Implemented |
NC0468 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,060 | $800 | Implemented |
NC0423 # 01 Y:2011 | 01 | 2011 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $1,468,749 | $650,000 | Implemented |
NC0423 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $4,313 | $12,378 | Not Implemented |
NC0423 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,230 | $4,585 | Implemented |
NC0423 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,209 | $115,608 | Implemented |
NC0423 # 04 Y:2011 | 04 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $24,869 | $42,000 | Not Implemented |
NC0423 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,736 | $100 | Implemented |
NC0423 # 03 Y:2011 | 03 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $26,211 | $60,000 | Not Implemented |
NC0423 # 05 Y:2011 | 05 | 2011 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $86,720 | $87,892 | Not Implemented |
NC0412 # 05 Y:2010 | 05 | 2010 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $7,153 | $15,100 | Implemented |