Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
68
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0277 # 03 Y:1996 | 03 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $952 | $3,840 | Implemented |
OR0277 # 02 Y:1996 | 02 | 1996 | USE OTHER WASTE CONCENTRATION METHODS | $5,324 | $10,000 | Implemented |
OR0277 # 01 Y:1996 | 01 | 1996 | USE OPTIMUM THICKNESS INSULATION | $12,794 | $20,784 | Not Implemented |
OR0273 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,150 | $6,000 | Not Implemented |
OR0273 # 05 Y:1996 | 05 | 1996 | USE OTHER WASTE CONCENTRATION METHODS | $45,735 | $67,500 | Not Implemented |
OR0273 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $947 | $5,575 | Not Implemented |
OR0273 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $803 | $1,775 | Implemented |
OR0273 # 02 Y:1996 | 02 | 1996 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,544 | $1,000 | Implemented |
OR0272 # 05 Y:1996 | 05 | 1996 | INSTALL SET-BACK TIMERS | $11,080 | $105,000 | Not Implemented |
OR0272 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $923 | $2,220 | Implemented |
OR0272 # 03 Y:1996 | 03 | 1996 | KEEP BOILER TUBES CLEAN | $1,014 | $1,000 | Not Implemented |
OR0272 # 02 Y:1996 | 02 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $247,053 | $1,000,000 | Implemented |
OR0272 # 01 Y:1996 | 01 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,768 | $11,600 | Not Implemented |
OR0271 # 07 Y:1996 | 07 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $5,480 | $3,000 | Implemented |
OR0271 # 06 Y:1996 | 06 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $160 | $0 | Not Implemented |
OR0271 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,740 | $16,120 | Implemented |
OR0271 # 04 Y:1996 | 04 | 1996 | KEEP BOILER TUBES CLEAN | $330 | $500 | Not Implemented |
OR0271 # 03 Y:1996 | 03 | 1996 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $10,070 | $6,000 | Not Implemented |
OR0271 # 01 Y:1996 | 01 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,100 | $0 | Not Implemented |
OR0271 # 02 Y:1996 | 02 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,000 | $5,000 | Implemented |
OR0259 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,337 | $11,047 | Not Implemented |
OR0259 # 06 Y:1996 | 06 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,611 | $0 | Implemented |
OR0259 # 01 Y:1996 | 01 | 1996 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $7,505 | $0 | Implemented |
OR0259 # 02 Y:1996 | 02 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $584 | $0 | Implemented |
OR0259 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $1,599 | $1,436 | Implemented |