Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

75

matching recommendations
Reset
NAICS 33211 Forging and Stamping
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0004 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,175 $39,950 Implemented
WM0004 # 04 Y:2012 04 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,511 $1,000 Implemented
WM0004 # 03 Y:2012 03 2012 COVER OPEN TANKS $1,078 $700 Not Implemented
WI0515 # 07 Y:2006 07 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $907 $0 Not Implemented
WI0515 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $972 $0 Not Implemented
WI0515 # 05 Y:2006 05 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,038 $1,280 Implemented
WI0515 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,559 $0 Implemented
WI0515 # 03 Y:2006 03 2006 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,857 $3,600 Not Implemented
WI0515 # 02 Y:2006 02 2006 $10,200 $0 Implemented
WI0515 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,672 $64,000 Not Implemented
WI0512 # 01 Y:2006 01 2006 $554 $21,500 Not Implemented
WI0512 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,679 $72,610 Implemented
WI0512 # 03 Y:2006 03 2006 USE EVAPORATION TO CONCENTRATE MATERIAL $24,691 $12,000 Not Implemented
WI0512 # 04 Y:2006 04 2006 $5,350 $0 Implemented
WI0512 # 05 Y:2006 05 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,371 $3,200 Not Implemented
WI0512 # 06 Y:2006 06 2006 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $843 $700 Implemented
WI0512 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $258 $150 Implemented
WI0452 # 01 Y:2003 01 2003 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $54,337 $72,000 n/a
WI0452 # 02 Y:2003 02 2003 BURN WASTE OIL FOR HEAT $44,636 $30,000 Not Implemented
WI0452 # 03 Y:2003 03 2003 UPGRADE CONTROLS ON COMPRESSORS $5,692 $12,000 Not Implemented
WI0452 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $4,850 $2,700 Not Implemented
WI0452 # 05 Y:2003 05 2003 REPLACE CLOTH RAGS WITH PAPER TOWELS $4,710 $0 Not Implemented
WI0452 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $4,063 $1,000 Not Implemented
WI0452 # 08 Y:2003 08 2003 USE OPTIMUM THICKNESS INSULATION $1,592 $687 Not Implemented
WI0452 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,926 $8,580 Not Implemented