Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,040
matching recommendationsNAICS | 2213 | Water, Sewage and Other Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0589 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,794 | $15,591 | Implemented |
SF0589 # 05 Y:2022 | 05 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,635 | $18,061 | Implemented |
SF0589 # 07 Y:2022 | 07 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $50,416 | $292,043 | Implemented |
WV0628 # 03 Y:2022 | 03 | 2022 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $8,049 | $1,000 | Implemented |
WV0628 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,802 | $3,626 | Implemented |
WV0628 # 07 Y:2022 | 07 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $371 | $1,608 | Implemented |
MA0843 # 03 Y:2022 | 03 | 2022 | USE HEAT PUMP FOR SPACE CONDITIONING | $11,001 | $6,450 | Implemented |
MA0843 # 04 Y:2022 | 04 | 2022 | USE HEAT PUMP FOR SPACE CONDITIONING | $7,677 | $3,875 | Implemented |
NL0068 # 01 Y:2022 | 01 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $44,258 | $7,000 | Implemented |
NL0068 # 02 Y:2022 | 02 | 2022 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $20,357 | $960 | Implemented |
NL0068 # 03 Y:2022 | 03 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $17,011 | $25,884 | Implemented |
NL0068 # 04 Y:2022 | 04 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,339 | $4,500 | Implemented |
NL0068 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,608 | $5,394 | Implemented |
MA0842 # 02 Y:2022 | 02 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,685 | $11,100 | Implemented |
MA0842 # 03 Y:2022 | 03 | 2022 | USE HEAT PUMP FOR SPACE CONDITIONING | $5,243 | $7,450 | Implemented |
MA0842 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,119 | $11,630 | Implemented |
AS0523 # 01 Y:2022 | 01 | 2022 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $42,697 | $89,337 | Implemented |
AS0523 # 02 Y:2022 | 02 | 2022 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,604 | $200 | Implemented |
AS0523 # 03 Y:2022 | 03 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,300 | $7,808 | Implemented |
AS0523 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,242 | $2,695 | Implemented |
AS0523 # 05 Y:2022 | 05 | 2022 | INSTALL OCCUPANCY SENSORS | $414 | $328 | Implemented |
AS0523 # 06 Y:2022 | 06 | 2022 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $381 | $32 | Implemented |
UF0581 # 02 Y:2022 | 02 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,084 | $4,202 | Implemented |
UF0581 # 03 Y:2022 | 03 | 2022 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,046 | $5,794 | Implemented |
UF0581 # 04 Y:2022 | 04 | 2022 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $5,091 | $8,250 | Implemented |