Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
415
matching recommendationsNAICS | 31142 | Fruit and Vegetable Canning, Pickling, and Drying |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0839 # 12 Y:2011 | 12 | 2011 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,987 | $993 | Implemented |
UD0839 # 13 Y:2011 | 13 | 2011 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $48,911 | $75,000 | Implemented |
MI0209 # 01 Y:2011 | 01 | 2011 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $4,297,734 | $3,000,000 | Implemented |
MI0209 # 04 Y:2011 | 04 | 2011 | REPLACE TREATED WATER WITH WELL / SURFACE WATER | $132,137 | $500,000 | Implemented |
MI0209 # 05 Y:2011 | 05 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $112,996 | $1,950 | Implemented |
MI0209 # 06 Y:2011 | 06 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $107,940 | $330,568 | Implemented |
MI0209 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,204 | $29,679 | Implemented |
MI0209 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27,599 | $1,320 | Implemented |
MI0209 # 09 Y:2011 | 09 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $13,681 | $50 | Implemented |
MI0209 # 12 Y:2011 | 12 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,268 | $3,200 | Implemented |
MI0209 # 14 Y:2011 | 14 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,235 | $3,450 | Implemented |
MI0209 # 15 Y:2011 | 15 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,926 | $3,450 | Implemented |
SU0303 # 01 Y:2011 | 01 | 2011 | INSULATE FEEDWATER TANK | $273 | $83 | Implemented |
SU0303 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $858 | $486 | Implemented |
SU0303 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $104 | $128 | Implemented |
LE0312 # 03 Y:2011 | 03 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $24,192 | $75,014 | Implemented |
LE0312 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $15,944 | $70 | Implemented |
LE0312 # 06 Y:2011 | 06 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $8,883 | $2,500 | Implemented |
LE0312 # 07 Y:2011 | 07 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $8,857 | $0 | Implemented |
LE0312 # 08 Y:2011 | 08 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,822 | $49,208 | Implemented |
LE0312 # 11 Y:2011 | 11 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,507 | $1,760 | Implemented |
DL0057 # 02 Y:2010 | 02 | 2010 | CLOSE OFF UNNEEDED STEAM LINES | $8,876 | $415 | Implemented |
DL0057 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143,083 | $15,941 | Implemented |
DL0057 # 04 Y:2010 | 04 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,305 | $2,960 | Implemented |
DL0057 # 05 Y:2010 | 05 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $413,326 | $133,000 | Implemented |