Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
387
matching recommendationsNAICS | 3132 | Fabric Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0513 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $89,082 | $860 | Implemented |
NC0513 # 03 Y:2014 | 03 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $21,458 | $10,000 | Implemented |
NC0513 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,428 | $100 | Implemented |
NC0513 # 05 Y:2014 | 05 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $325 | $175 | Implemented |
NC0513 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,462 | $24,205 | Not Implemented |
NC0513 # 07 Y:2014 | 07 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,117 | $325 | Not Implemented |
NC0513 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $3,462 | $3,470 | Implemented |
NC0513 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $835 | $240 | Implemented |
NC0513 # 10 Y:2014 | 10 | 2014 | USE PHOTOCELL CONTROLS | $47 | $80 | Not Implemented |
NC0513 # 11 Y:2014 | 11 | 2014 | KEEP BOILER TUBES CLEAN | $48,265 | $15,000 | Implemented |
NC0513 # 12 Y:2014 | 12 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $40,007 | $6,200 | Implemented |
NC0513 # 13 Y:2014 | 13 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $20,840 | $20,000 | Implemented |
NC0513 # 14 Y:2014 | 14 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,159 | $5,600 | Not Implemented |
NC0513 # 15 Y:2014 | 15 | 2014 | KEEP BOILER TUBES CLEAN | $13,546 | $500 | Not Implemented |
NC0513 # 16 Y:2014 | 16 | 2014 | INSULATE FEEDWATER TANK | $438 | $257 | Implemented |
NC0513 # 17 Y:2014 | 17 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $20,435 | $19,607 | Not Implemented |
NC0513 # 18 Y:2014 | 18 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,375 | $37,264 | Not Implemented |
NC0510 # 13 Y:2014 | 13 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $2,594 | $4,256 | Not Implemented |
NC0510 # 14 Y:2014 | 14 | 2014 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,665 | $8,500 | Not Implemented |
NC0510 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $55,430 | $1,200 | Implemented |
NC0510 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,472 | $4,800 | Not Implemented |
NC0510 # 03 Y:2014 | 03 | 2014 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $1,500 | $1,000 | Implemented |
NC0510 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $39,042 | $3,000 | Not Implemented |
NC0510 # 05 Y:2014 | 05 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $26,718 | $67,500 | Implemented |
NC0510 # 12 Y:2014 | 12 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $533 | $286 | Not Implemented |