Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

377

matching recommendations
Reset
NAICS 3132 Fabric Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0513 # 12 Y:2014 12 2014 REPAIR OR REPLACE STEAM TRAPS $40,007 $6,200 Implemented
NC0513 # 13 Y:2014 13 2014 REPAIR AND ELIMINATE STEAM LEAKS $20,840 $20,000 Implemented
NC0513 # 14 Y:2014 14 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $9,159 $5,600 Not Implemented
NC0513 # 15 Y:2014 15 2014 KEEP BOILER TUBES CLEAN $13,546 $500 Not Implemented
NC0513 # 16 Y:2014 16 2014 INSULATE FEEDWATER TANK $438 $257 Implemented
NC0513 # 17 Y:2014 17 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $20,435 $19,607 Not Implemented
NC0513 # 18 Y:2014 18 2014 RECOVER WASTE HEAT FROM EQUIPMENT $9,375 $37,264 Not Implemented
NC0510 # 01 Y:2014 01 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $55,430 $1,200 Implemented
NC0510 # 13 Y:2014 13 2014 DEVELOP A REPAIR/REPLACE POLICY $2,594 $4,256 Not Implemented
NC0510 # 12 Y:2014 12 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $533 $286 Not Implemented
NC0510 # 11 Y:2014 11 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $836 $240 Implemented
NC0510 # 10 Y:2014 10 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $811 $3,523 Implemented
NC0510 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $943 $1,993 Implemented
NC0510 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $1,444 $2,082 Implemented
NC0510 # 07 Y:2014 07 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,422 $100 Implemented
NC0510 # 06 Y:2014 06 2014 RECOVER WASTE HEAT FROM EQUIPMENT $9,896 $1,750 Not Implemented
NC0510 # 05 Y:2014 05 2014 REPAIR OR REPLACE STEAM TRAPS $26,718 $67,500 Implemented
NC0510 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $39,042 $3,000 Not Implemented
NC0510 # 03 Y:2014 03 2014 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $1,500 $1,000 Implemented
NC0510 # 02 Y:2014 02 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $5,472 $4,800 Not Implemented
NC0510 # 14 Y:2014 14 2014 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $2,665 $8,500 Not Implemented
OR0624 # 01 Y:2014 01 2014 UPGRADE CONTROLS ON COMPRESSORS $8,251 $22,500 Not Implemented
OR0624 # 02 Y:2014 02 2014 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $2,193 $468 Not Implemented
OR0624 # 03 Y:2014 03 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $12,766 $6,839 Implemented
OR0624 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,361 $30,178 Implemented