Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
314
matching recommendationsNAICS | 3221 | Pulp, Paper, and Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0675 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $2,590 | $950 | Implemented |
LL0333 # 01 Y:2010 | 01 | 2010 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,585,020 | $273,500 | Implemented |
LL0333 # 02 Y:2010 | 02 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $288,465 | $36,500 | Implemented |
LL0333 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $3,966 | $5,315 | Implemented |
SU0297 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $30,345 | $0 | Implemented |
SU0297 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $11,458 | $697 | Implemented |
SU0297 # 05 Y:2010 | 05 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $29,835 | $5,275 | Implemented |
SU0297 # 06 Y:2010 | 06 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,260 | $650 | Implemented |
SU0297 # 08 Y:2010 | 08 | 2010 | OPTIMIZE PLANT POWER FACTOR | $18,693 | $24,129 | Implemented |
SU0297 # 10 Y:2010 | 10 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,058 | $45,795 | Implemented |
SU0297 # 11 Y:2010 | 11 | 2010 | UPGRADE OBSOLETE EQUIPMENT | $1,054 | $4,725 | Implemented |
WV0401 # 14 Y:2010 | 14 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $536 | $52 | Implemented |
WV0401 # 13 Y:2010 | 13 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,239 | $1,000 | Implemented |
WV0401 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,182 | $2,886 | Implemented |
WV0401 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,622 | $312 | Implemented |
WV0401 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,432 | $2,028 | Implemented |
WV0401 # 06 Y:2010 | 06 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,226 | $20,400 | Implemented |
WV0401 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,792 | $7,958 | Implemented |
WV0401 # 03 Y:2010 | 03 | 2010 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $38,419 | $128,000 | Implemented |
WV0401 # 02 Y:2010 | 02 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $57,379 | $6,240 | Implemented |
MI0188 # 01 Y:2010 | 01 | 2010 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $500,499 | $0 | Implemented |
MI0188 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $42,782 | $60 | Implemented |
MI0188 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,420 | $920 | Implemented |
MI0188 # 06 Y:2010 | 06 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,600 | $1,920 | Implemented |
MI0188 # 08 Y:2010 | 08 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,050 | $2,904 | Implemented |