Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

540

matching recommendations
Reset
NAICS 32412 Asphalt Paving, Roofing, and Saturated Materials Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0719 # 06 Y:2006 06 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $221 $225 Implemented
OK0719 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $49 $92 Not Implemented
CO0580 # 01 Y:2006 01 2006 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT $479,740 $28,080 Not Implemented
CO0580 # 02 Y:2006 02 2006 REPAIR AND ELIMINATE STEAM LEAKS $10,650 $500 Implemented
CO0580 # 03 Y:2006 03 2006 INSULATE BARE EQUIPMENT $9,880 $3,190 Not Implemented
CO0580 # 04 Y:2006 04 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $3,750 $12,850 Implemented
CO0580 # 05 Y:2006 05 2006 DIRECT WARMEST AIR TO COMBUSTION INTAKE $3,310 $980 Implemented
CO0580 # 06 Y:2006 06 2006 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,460 $9,360 Not Implemented
CO0580 # 07 Y:2006 07 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $50 $20 Implemented
CO0580 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $900 $1,610 Not Implemented
CO0580 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $660 $1,830 Implemented
CO0580 # 10 Y:2006 10 2006 USE SOLAR HEAT FOR HEAT $470 $1,400 Not Implemented
CO0580 # 11 Y:2006 11 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $280 $500 Implemented
UF0368 # 01 Y:2005 01 2005 OPTIMIZE PLANT POWER FACTOR $47,282 $35,000 Not Implemented
UF0368 # 02 Y:2005 02 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,231 $3,846 Implemented
UF0368 # 03 Y:2005 03 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,367 $1,437 Implemented
UF0368 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $1,437 $1,407 Implemented
UF0368 # 05 Y:2005 05 2005 INSULATE BARE EQUIPMENT $194 $65 Implemented
UF0368 # 06 Y:2005 06 2005 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $340 $316 Implemented
UF0368 # 07 Y:2005 07 2005 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $6,000 $2,304 Implemented
UF0368 # 08 Y:2005 08 2005 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $6,656 $5,000 Implemented
SF0315 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2 $312 Implemented
SF0315 # 02 Y:2005 02 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $2 $206 Implemented
SF0315 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $192 $1,531 Not Implemented
SF0315 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $16 $8,242 Not Implemented