Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
427
matching recommendationsNAICS | 32519 | Other Basic Organic Chemical Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UMS005 # 01 Y:2012 | 01 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,330,000 | $1,500,000 | Not Implemented |
UMS005 # 02 Y:2012 | 02 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $107,000 | $50,000 | Not Implemented |
UMS005 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $305,000 | $300,000 | Not Implemented |
BD0387 # 01 Y:2011 | 01 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $25,233 | $21,500 | Implemented |
BD0387 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $3,064 | Implemented |
BD0387 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,861 | $600 | Implemented |
BD0387 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,318 | $200 | Not Implemented |
BD0387 # 05 Y:2011 | 05 | 2011 | MINIMIZE WATER USAGE | $2,025 | $1,600 | Not Implemented |
BD0387 # 06 Y:2011 | 06 | 2011 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $374,556 | $995,000 | Not Implemented |
AM0594 # 01 Y:2011 | 01 | 2011 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $74,000 | $26,000 | Not Implemented |
AM0594 # 02 Y:2011 | 02 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,850 | $0 | Implemented |
AM0594 # 03 Y:2011 | 03 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,246 | $180 | Not Implemented |
AM0594 # 04 Y:2011 | 04 | 2011 | SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON | $1,150 | $0 | Not Implemented |
AM0594 # 05 Y:2011 | 05 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $650 | $270 | Implemented |
AM0594 # 06 Y:2011 | 06 | 2011 | USE SYNTHETIC LUBRICANT | $393 | $0 | Not Implemented |
WV0407 # 01 Y:2010 | 01 | 2010 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $622,016 | $798,300 | Not Implemented |
WV0407 # 02 Y:2010 | 02 | 2010 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $542,540 | $1,200,000 | Not Implemented |
WV0407 # 03 Y:2010 | 03 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $235,631 | $5,500 | Implemented |
WV0407 # 04 Y:2010 | 04 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $43,962 | $96,200 | Not Implemented |
WV0407 # 05 Y:2010 | 05 | 2010 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $20,301 | $7,920 | Not Implemented |
WV0407 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,102 | $43,400 | Not Implemented |
WV0407 # 07 Y:2010 | 07 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $10,842 | $772 | Implemented |
WV0407 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,003 | $17,348 | Implemented |
WV0407 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,209 | $7,158 | Implemented |
WV0407 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,353 | $1,000 | Implemented |