Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

333

matching recommendations
Reset
NAICS 325199 All Other Basic Organic Chemical Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0407 # 09 Y:2010 09 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,209 $7,158 Implemented
WV0407 # 10 Y:2010 10 2010 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,353 $1,000 Implemented
UF0432 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $33,739 $32,047 Not Implemented
UF0432 # 02 Y:2010 02 2010 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $4,188 $5,591 Not Implemented
UF0432 # 03 Y:2010 03 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $14,940 $2,240 Not Implemented
UF0432 # 04 Y:2010 04 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,539 $719 Not Implemented
UF0432 # 05 Y:2010 05 2010 USE PHOTOCELL CONTROLS $6,416 $768 Not Implemented
UF0432 # 11 Y:2010 11 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,637 $1,500 Not Implemented
UF0432 # 10 Y:2010 10 2010 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $3,120 $0 Not Implemented
UF0432 # 09 Y:2010 09 2010 CLEAN CONDENSER TUBES $1,343 $120 Not Implemented
UF0432 # 08 Y:2010 08 2010 DEVELOP A REPAIR/REPLACE POLICY $364 $0 Not Implemented
UF0432 # 07 Y:2010 07 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,000 $2,700 Not Implemented
UF0432 # 06 Y:2010 06 2010 INSTALL COMMON HEADER ON COMPRESSORS $1,520 $0 Not Implemented
IC0153 # 01 Y:2009 01 2009 INSTALL OCCUPANCY SENSORS $1,078 $642 Not Implemented
IC0153 # 02 Y:2009 02 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $206 $0 Not Implemented
IC0153 # 03 Y:2009 03 2009 USE SOLAR HEAT TO HEAT WATER $605 $2,240 Not Implemented
OR0540 # 01 Y:2008 01 2008 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $29 $10,000 Implemented
OR0540 # 02 Y:2008 02 2008 INCREASE AMOUNT OF CONDENSATE RETURNED $14,149 $6,100 Implemented
OR0540 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $2,932 $13,049 Implemented
OR0540 # 04 Y:2008 04 2008 USE SOLAR HEAT TO MAKE ELECTRICTY $23,433 $257,380 Not Implemented
OR0540 # 05 Y:2008 05 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $434 $12,400 Not Implemented
OR0540 # 06 Y:2008 06 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,216 $0 Not Implemented
OR0540 # 07 Y:2008 07 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $699 $1,398 Not Implemented
OR0540 # 08 Y:2008 08 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $341 $0 Not Implemented
NC0383 # 01 Y:2008 01 2008 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $16,582 $1,000 Implemented