IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

238

matching recommendations
Reset
NAICS 326 Plastics and Rubber Products Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0085 # 07 Y:2012 07 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $421 $3,440 Implemented
TT0085 # 08 Y:2012 08 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $312 $4,158 Implemented
TT0085 # 09 Y:2012 09 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $83,427 $175,342 Implemented
TT0082 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,923 $18,044 Implemented
TT0082 # 02 Y:2011 02 2011 INSTALL OCCUPANCY SENSORS $4,602 $28,092 Not Implemented
TT0082 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,878 $11,643 Not Implemented
TT0082 # 04 Y:2011 04 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,256 $1,480 Implemented
TT0082 # 05 Y:2011 05 2011 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,673 $15 Implemented
TT0082 # 06 Y:2011 06 2011 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $2,834 $1,500 Not Implemented
TT0082 # 07 Y:2011 07 2011 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS $952 $2,625 Implemented
TT0065 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,010 $5,000 Not Implemented
TT0065 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,300 $32,200 Not Implemented
TT0065 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $39,600 $109,700 Not Implemented
TT0065 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,200 $3,700 Not Implemented
TT0065 # 05 Y:2011 05 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,000 $12,200 Implemented
TT0065 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,990 $5,000 Implemented
TT0065 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $9,600 $10,000 Not Implemented
TT0065 # 08 Y:2011 08 2011 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $20,800 $22,000 Not Implemented
TT0065 # 09 Y:2011 09 2011 INSULATE BARE EQUIPMENT $65,500 $61,500 Implemented
TT0055 # 01 Y:2010 01 2010 REDUCE VENTILATION AIR $5,009 $17,120 Not Implemented
TT0055 # 02 Y:2010 02 2010 OPTIMIZE PLANT POWER FACTOR $11,430 $13,000 Implemented
TT0055 # 03 Y:2010 03 2010 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $560 $825 Implemented
TT0055 # 04 Y:2010 04 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $1,500 $632 Not Implemented
TT0055 # 05 Y:2010 05 2010 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $520 $15 Implemented
TT0055 # 06 Y:2010 06 2010 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $253 $250 Implemented