Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsNAICS | 32629 | Other Rubber Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0324 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,504 | $70 | Implemented |
SD0319 # 10 Y:2003 | 10 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,780 | $1,550 | Implemented |
SD0319 # 13 Y:2003 | 13 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,005 | $1,500 | Implemented |
SD0319 # 15 Y:2003 | 15 | 2003 | CLOSE OFF UNNEEDED STEAM LINES | $2,248 | $1,350 | Implemented |
SD0319 # 16 Y:2003 | 16 | 2003 | REDUCE SCRAP PRODUCTION | $222,070 | $9,000 | Implemented |
SD0319 # 19 Y:2003 | 19 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,166 | $0 | Implemented |
SD0319 # 05 Y:2003 | 05 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $22,467 | $9,950 | Implemented |
OK0658 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,150 | $5,273 | Implemented |
OK0658 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,978 | $367 | Implemented |
OK0658 # 03 Y:2003 | 03 | 2003 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,031 | $0 | Implemented |
OK0658 # 01 Y:2003 | 01 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $51,704 | $45,000 | Implemented |
OK0658 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,609 | $30,876 | Implemented |
OK0658 # 09 Y:2003 | 09 | 2003 | INSTALL OCCUPANCY SENSORS | $6,270 | $2,004 | Implemented |
WI0438 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,005 | $15,000 | Implemented |
WI0438 # 02 Y:2003 | 02 | 2003 | SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM | $4,455 | $5,000 | Implemented |
WI0438 # 04 Y:2003 | 04 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,901 | $1,000 | Implemented |
WI0438 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,793 | $2,800 | Implemented |
WI0438 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $353 | $120 | Implemented |
IC0054 # 01 Y:2003 | 01 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $358 | $1,074 | Implemented |
UM0224 # 12 Y:2003 | 12 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $31,000 | $2,500 | Implemented |
UM0224 # 09 Y:2003 | 09 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,650 | $120 | Implemented |
UM0224 # 07 Y:2003 | 07 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,606 | $934 | Implemented |
UM0224 # 05 Y:2003 | 05 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $26,100 | $7,230 | Implemented |
UM0224 # 04 Y:2003 | 04 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $51,840 | $5,520 | Implemented |
UM0224 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $21,643 | $15,930 | Implemented |