Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
90
matching recommendationsNAICS | 327 | Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3026 # 06 Y:2013 | 06 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $5,142 | $300 | Not Implemented |
UA3026 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $21,524 | $800 | Implemented |
UA3026 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $29,047 | $800 | Implemented |
UA3026 # 01 Y:2013 | 01 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $65,646 | $30,000 | Not Implemented |
UA0051 # 05 Y:2010 | 05 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $8,177 | $5,219 | Implemented |
UA0051 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,331 | $640 | Not Implemented |
UA0051 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,427 | $4,500 | Implemented |
UA0051 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,840 | $10,000 | Implemented |
UA0051 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $9,487 | $1,000 | Not Implemented |
UA0051 # 06 Y:2010 | 06 | 2010 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $48,136 | $21,075 | Not Implemented |
UA0033 # 04 Y:2009 | 04 | 2009 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $61,530 | $16,083 | Not Implemented |
UA0033 # 03 Y:2009 | 03 | 2009 | INSULATE BARE EQUIPMENT | $570 | $2,548 | Not Implemented |
UA0033 # 02 Y:2009 | 02 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $96,325 | $7,930 | Not Implemented |
UA0033 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $970 | $700 | Not Implemented |
UA0022 # 01 Y:2008 | 01 | 2008 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $204,109 | $300,000 | Not Implemented |
UA0022 # 02 Y:2008 | 02 | 2008 | USE OPTIMUM THICKNESS INSULATION | $12,433 | $2,976 | Not Implemented |
UA0022 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,260 | $33,777 | Not Implemented |
UA0022 # 04 Y:2008 | 04 | 2008 | USE PHOTOCELL CONTROLS | $3,768 | $1,894 | Not Implemented |
UA0022 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $186 | $300 | Implemented |
UA0022 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,127 | $0 | Not Implemented |
UA0022 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,161 | $3,000 | Implemented |
UA0022 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,504 | $1,845 | Implemented |
UA0022 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $994 | $10,283 | Implemented |
UA0014 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,454 | $591 | Implemented |
UA0014 # 01 Y:2008 | 01 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,796 | $0 | Implemented |