IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

998

matching recommendations
Reset
NAICS 33152 Nonferrous Metal Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0412 # 06 Y:2009 06 2009 INSTALL SKYLIGHTS $3,365 $9,170 Implemented
TT0026 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,300 $63,800 Not Implemented
TT0026 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,980 $6,600 Not Implemented
TT0026 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,430 $3,640 Not Implemented
TT0026 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $590 Not Implemented
TT0026 # 05 Y:2008 05 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,119 $55,000 Not Implemented
TT0026 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,000 $4,900 Not Implemented
TT0026 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $25,000 $1,000 Not Implemented
TT0026 # 08 Y:2008 08 2008 OPTIMIZE PLANT POWER FACTOR $1,150 $6,000 Not Implemented
UF0413 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,814 $810 Implemented
UF0413 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34,500 $54,000 Implemented
UF0413 # 03 Y:2008 03 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,206 $16,270 Not Implemented
UF0413 # 04 Y:2008 04 2008 INSTALL OCCUPANCY SENSORS $1,150 $219 Implemented
UF0413 # 05 Y:2008 05 2008 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $14,800 $1,117 Implemented
UF0413 # 06 Y:2008 06 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,321 $13,321 Implemented
UF0413 # 07 Y:2008 07 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,742 $20,000 Not Implemented
UF0413 # 08 Y:2008 08 2008 INSTALL COMMON HEADER ON COMPRESSORS $871 $2,000 Implemented
UF0413 # 09 Y:2008 09 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $151,840 $16,695 Not Implemented
UF0413 # 10 Y:2008 10 2008 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $9,571 $1,500 Not Implemented
UW0018 # 01 Y:2008 01 2008 UTILIZE JOB COSTING SOFTWARE $55,734 $72,000 Not Implemented
UW0018 # 02 Y:2008 02 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,434 $34,000 Not Implemented
UW0018 # 03 Y:2008 03 2008 USE OPTIMUM THICKNESS INSULATION $9,391 $39,900 Not Implemented
UW0018 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,375 $4,328 Not Implemented
UW0018 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,037 $2,775 Not Implemented
BD0346 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $84,447 $2,972 Implemented