Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
105
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0689 # 03 Y:2014 | 03 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,260 | $1,500 | Not Implemented |
CO0689 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,950 | $18,390 | Not Implemented |
CO0689 # 02 Y:2014 | 02 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,310 | $23,560 | Not Implemented |
CO0689 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,480 | $4,200 | Not Implemented |
CO0681 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,610 | $8,490 | Not Implemented |
CO0681 # 03 Y:2014 | 03 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $175,400 | $229,810 | Implemented |
CO0681 # 02 Y:2014 | 02 | 2014 | INSULATE BARE EQUIPMENT | $3,470 | $900 | Not Implemented |
CO0681 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,480 | $13,140 | Not Implemented |
CO0675 # 01 Y:2013 | 01 | 2013 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $30,250 | $172,320 | Not Implemented |
CO0675 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $270 | $290 | Implemented |
CO0675 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $810 | $1,280 | Not Implemented |
CO0675 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,730 | $18,100 | Not Implemented |
CO0670 # 05 Y:2013 | 05 | 2013 | USE EVAPORATION TO CONCENTRATE MATERIAL | $660 | $0 | Implemented |
CO0670 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $1,160 | $330 | Implemented |
CO0670 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,800 | $620 | Implemented |
CO0670 # 06 Y:2013 | 06 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,080 | $500 | Implemented |
CO0670 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,830 | $25,400 | Not Implemented |
CO0670 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,960 | $670 | Implemented |
CO0659 # 01 Y:2012 | 01 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,680 | $25,960 | Implemented |
CO0659 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $380 | $1,240 | Not Implemented |
CO0659 # 05 Y:2012 | 05 | 2012 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,570 | $0 | Implemented |
CO0659 # 04 Y:2012 | 04 | 2012 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,180 | $500 | Not Implemented |
CO0659 # 03 Y:2012 | 03 | 2012 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $21,530 | $6,400 | Not Implemented |
CO0659 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,470 | $500 | Implemented |
CO0639 # 06 Y:2010 | 06 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,050 | $35,000 | Not Implemented |