Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
105
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0639 # 02 Y:2010 | 02 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,600 | $10,320 | Not Implemented |
CO0639 # 03 Y:2010 | 03 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,040 | $13,990 | Not Implemented |
CO0639 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,710 | $33,800 | Not Implemented |
CO0639 # 05 Y:2010 | 05 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,060 | $3,620 | Not Implemented |
CO0639 # 06 Y:2010 | 06 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $2,050 | $35,000 | Not Implemented |
CO0598 # 01 Y:2007 | 01 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $77,320 | $140,620 | Not Implemented |
CO0598 # 02 Y:2007 | 02 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $37,380 | $112,000 | Not Implemented |
CO0598 # 03 Y:2007 | 03 | 2007 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $15,090 | $338,400 | Not Implemented |
CO0598 # 04 Y:2007 | 04 | 2007 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,960 | $14,520 | Not Implemented |
CO0598 # 05 Y:2007 | 05 | 2007 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,660 | $4,250 | Not Implemented |
CO0598 # 06 Y:2007 | 06 | 2007 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,310 | $11,000 | Not Implemented |
CO0583 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $213,730 | $703,800 | Not Implemented |
CO0583 # 02 Y:2006 | 02 | 2006 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $31,500 | $1,420 | Implemented |
CO0583 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,120 | $4,920 | Implemented |
CO0583 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,990 | $200 | Implemented |
CO0583 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $480 | $165 | Implemented |
CO0583 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $34,970 | $37,470 | Not Implemented |
CO0583 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,400 | $9,510 | Implemented |
CO0583 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,800 | $2,380 | Implemented |
CO0583 # 09 Y:2006 | 09 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,450 | $18,370 | Not Implemented |
CO0563 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $56,710 | $346,448 | Implemented |
CO0563 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $26,550 | $89,981 | Implemented |
CO0563 # 03 Y:2005 | 03 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,440 | $9,180 | Not Implemented |
CO0563 # 04 Y:2005 | 04 | 2005 | USE SYNTHETIC LUBRICANT | $2,710 | $1,660 | Not Implemented |
CO0563 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $820 | $0 | Implemented |