Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0484 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,500 | $1,740 | Implemented |
AM0484 # 03 Y:2005 | 03 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,560 | $360 | Implemented |
AM0484 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,000 | $20 | Implemented |
AM0484 # 05 Y:2005 | 05 | 2005 | USE SYNTHETIC LUBRICANT | $600 | $0 | Implemented |
AM0484 # 06 Y:2005 | 06 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $410 | $470 | Not Implemented |
AM0484 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $330 | $400 | Implemented |
UF0356 # 01 Y:2005 | 01 | 2005 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $0 | $150,000 | Not Implemented |
UF0356 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,843 | $21,108 | Implemented |
UF0356 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,348 | $2,000 | Implemented |
UF0356 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,008 | $700 | Implemented |
UF0356 # 05 Y:2005 | 05 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,918 | $1,185 | Not Implemented |
UF0356 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,295 | $2,194 | Implemented |
UF0356 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,232 | $1,450 | Implemented |
UF0356 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $96 | $245 | Implemented |
UF0356 # 09 Y:2005 | 09 | 2005 | RECYCLE FLUORESCENT LAMPS | $0 | $3,496 | Implemented |
TA0091 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,915 | $975 | Not Implemented |
TA0091 # 02 Y:2005 | 02 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,600 | $4,390 | Not Implemented |
TA0091 # 03 Y:2005 | 03 | 2005 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,910 | $2,332 | Not Implemented |
TA0091 # 04 Y:2005 | 04 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,750 | $190 | Not Implemented |
TA0091 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $892 | $117 | Not Implemented |
TA0091 # 06 Y:2005 | 06 | 2005 | USE PHOTOCELL CONTROLS | $520 | $15 | Not Implemented |
LM0090 # 01 Y:2005 | 01 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,633 | $0 | Not Implemented |
LM0090 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $429 | $280 | Implemented |
LM0090 # 03 Y:2005 | 03 | 2005 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,100 | $0 | Not Implemented |
LM0090 # 04 Y:2005 | 04 | 2005 | DEVELOP STANDARD OPERATING PROCEDURES | $2,898 | $2,000 | Not Implemented |