Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsNAICS | 333314 | Optical Instrument and Lens Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0697 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,760 | $1,550 | Not Implemented |
CO0697 # 03 Y:2014 | 03 | 2014 | USE SOLAR HEAT TO MAKE ELECTRICTY | $13,090 | $87,610 | Not Implemented |
CO0697 # 04 Y:2014 | 04 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $8,560 | $38,890 | Not Implemented |
CO0697 # 05 Y:2014 | 05 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,000 | $500 | Not Implemented |
CO0697 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,440 | $5,180 | Not Implemented |
SF0449 # 01 Y:2014 | 01 | 2014 | INSTALL SPECTRAL REFLECTORS / DELAMP | $660 | $280 | Implemented |
SF0449 # 02 Y:2014 | 02 | 2014 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,804 | $9,262 | Not Implemented |
SF0449 # 03 Y:2014 | 03 | 2014 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $317 | $307 | Not Implemented |
SF0449 # 04 Y:2014 | 04 | 2014 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $28,600 | $42,672 | Not Implemented |
SF0449 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,630 | $27,842 | Implemented |
SF0449 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $2,997 | $14,024 | Not Implemented |
CO0682 # 01 Y:2014 | 01 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,080 | $9,950 | Not Implemented |
CO0682 # 02 Y:2014 | 02 | 2014 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $42,490 | $93,580 | Not Implemented |
CO0682 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,860 | $5,750 | Not Implemented |
CO0682 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $1,250 | $1,240 | Not Implemented |
MA0708 # 01 Y:2013 | 01 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,752 | $30,000 | Not Implemented |
MA0708 # 02 Y:2013 | 02 | 2013 | REDUCE VENTILATION AIR | $3,194 | $7,450 | Not Implemented |
MA0708 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,140 | $400 | Implemented |
MA0708 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,828 | $3,200 | Implemented |
MI0237 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,474 | $10,160 | Implemented |
MI0237 # 02 Y:2013 | 02 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,857 | $80 | Implemented |
MI0237 # 03 Y:2013 | 03 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $5,143 | $2,188 | Not Implemented |
MI0237 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,086 | $80 | Implemented |
MI0237 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,565 | $1,660 | Implemented |
MI0237 # 06 Y:2013 | 06 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,104 | $2,406 | Implemented |