Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
58
matching recommendationsNAICS | 33341 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0062 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,003 | $6,290 | Implemented |
LM0062 # 06 Y:2003 | 06 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $3,170 | $1,950 | Not Implemented |
OK0661 # 06 Y:2003 | 06 | 2003 | USE COMPRESSOR AIR FILTERS | $3,339 | $168 | Not Implemented |
OK0661 # 05 Y:2003 | 05 | 2003 | OPTIMIZE PLANT POWER FACTOR | $1,271 | $3,206 | Not Implemented |
OK0661 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,319 | $823 | Implemented |
OK0661 # 03 Y:2003 | 03 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,245 | $7,483 | Not Implemented |
OK0661 # 02 Y:2003 | 02 | 2003 | $20,400 | $0 | Implemented | |
OK0661 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $72,173 | $0 | Not Implemented |
OK0661 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $441 | $262 | Not Implemented |
OK0661 # 08 Y:2003 | 08 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,061 | $45,000 | Implemented |
OK0661 # 09 Y:2003 | 09 | 2003 | $11,440 | $2,500 | Implemented | |
SU0161 # 08 Y:2003 | 08 | 2003 | INSTALL OCCUPANCY SENSORS | $95 | $70 | Not Implemented |
SU0161 # 07 Y:2003 | 07 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $218 | $0 | Not Implemented |
SU0161 # 06 Y:2003 | 06 | 2003 | USE SYNTHETIC LUBRICANT | $272 | $800 | Not Implemented |
SU0161 # 05 Y:2003 | 05 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $468 | $748 | Not Implemented |
SU0161 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $531 | $1,608 | Not Implemented |
SU0161 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $580 | $2,033 | Not Implemented |
SU0161 # 02 Y:2003 | 02 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,035 | $540 | Implemented |
SU0161 # 01 Y:2003 | 01 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $12,003 | $16,100 | Implemented |
MS0221 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,072 | $12,006 | Not Implemented |
MS0221 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $460 | $585 | Not Implemented |
MS0221 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,834 | $782 | Implemented |
MS0221 # 01 Y:2003 | 01 | 2003 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $202,950 | $8,100 | Implemented |
SU0153 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57,642 | $93,355 | Implemented |
SU0153 # 02 Y:2003 | 02 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $42,094 | $93,819 | Not Implemented |