Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
223
matching recommendationsNAICS | 3336 | Engine, Turbine, and Power Transmission Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0254 # 13 Y:2004 | 13 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,580 | $240 | Implemented |
LM0070 # 01 Y:2004 | 01 | 2004 | DISCONNECT BALLASTS | $4,442 | $0 | Implemented |
LM0070 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $1,970 | $110 | Implemented |
LM0070 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,020 | $1,000 | Implemented |
LM0070 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $486 | $0 | Implemented |
LM0070 # 07 Y:2004 | 07 | 2004 | MODIFY STARTUP/SHUTDOWN TIMES | $13,976 | $1,000 | Implemented |
LM0070 # 08 Y:2004 | 08 | 2004 | ELIMINATE SHIFT | $15,698 | $1,000 | Implemented |
LM0070 # 09 Y:2004 | 09 | 2004 | MODIFY WORKLOAD | $855,000 | $50,000 | Implemented |
NC0271 # 01 Y:2003 | 01 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,523 | $50 | Implemented |
NC0271 # 05 Y:2003 | 05 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $204 | $150 | Implemented |
NC0271 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $796 | $100 | Implemented |
IC0070 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $56,367 | $4,200 | Implemented |
IC0070 # 07 Y:2003 | 07 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,133 | $0 | Implemented |
IC0067 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,779 | $2,600 | Implemented |
IC0067 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,485 | $0 | Implemented |
IC0067 # 06 Y:2003 | 06 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,376 | $0 | Implemented |
LL0174 # 02 Y:2003 | 02 | 2003 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,785 | $880 | Implemented |
LL0174 # 04 Y:2003 | 04 | 2003 | USE PHOTOCELL CONTROLS | $582 | $28 | Implemented |
LL0174 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $384 | $56 | Implemented |
LL0174 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $386 | $280 | Implemented |
NC0263 # 04 Y:2003 | 04 | 2003 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $47,210 | $100,000 | Implemented |
NC0263 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $556 | $680 | Implemented |
NC0263 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $413 | $240 | Implemented |