IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

25

matching recommendations
Reset
NAICS 3345 Navigational, Measuring, Electromedical, and Control Instruments Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD1044 # 04 Y:2022 04 2022 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $318 $0 Implemented
CW0119 # 07 Y:2021 07 2021 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $5,837 $1,000 Implemented
CW0119 # 05 Y:2021 05 2021 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,381 $6,000 Implemented
CW0119 # 02 Y:2021 02 2021 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $3,402 $1,640 Implemented
CW0119 # 01 Y:2021 01 2021 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,804 $0 Implemented
UD0951 # 06 Y:2016 06 2016 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,332 $3,750 Implemented
UD0850 # 10 Y:2012 10 2012 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,348 $9,000 Implemented
UD0850 # 09 Y:2012 09 2012 REDUCE VENTILATION AIR $2,781 $200 Implemented
UD0850 # 07 Y:2012 07 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $452 $1,000 Implemented
UD0850 # 06 Y:2012 06 2012 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $648 $0 Implemented
UD0850 # 04 Y:2012 04 2012 UPGRADE CONTROLS ON COMPRESSORS $15,877 $33,000 Implemented
UD0850 # 03 Y:2012 03 2012 KEEP LAMPS AND REFLECTORS CLEAN $362 $374 Implemented
UD0796 # 12 Y:2009 12 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $284 $0 Implemented
UD0796 # 13 Y:2009 13 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $149 $0 Implemented
UD0796 # 10 Y:2009 10 2009 INSTALL AUTOMATIC STACK DAMPER $418 $400 Implemented
UD0796 # 09 Y:2009 09 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $788 $0 Implemented
UD0796 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $935 $2,115 Implemented
UD0796 # 06 Y:2009 06 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,734 $500 Implemented
UD0796 # 04 Y:2009 04 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $4,088 $0 Implemented
UD0796 # 03 Y:2009 03 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $9,237 $0 Implemented
UD0796 # 02 Y:2009 02 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $9,992 $1,525 Implemented
UD0796 # 01 Y:2009 01 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $17,000 $4,900 Implemented
UD0713 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $1,021 $3,807 Implemented
UD0713 # 06 Y:2005 06 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,925 $200 Implemented
UD0713 # 03 Y:2005 03 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,435 $41,783 Implemented