Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
375
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0005 # 03 Y:2012 | 03 | 2012 | INSULATE BARE EQUIPMENT | $683 | $0 | Implemented |
IP0005 # 04 Y:2012 | 04 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $997 | $1,803 | Not Implemented |
IP0005 # 05 Y:2012 | 05 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $16,542 | $37,000 | Not Implemented |
NC0472 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $845 | $1,125 | Not Implemented |
NC0472 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,563 | $16,950 | Implemented |
TT0098 # 05 Y:2012 | 05 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $7,381 | $980 | Implemented |
TT0098 # 04 Y:2012 | 04 | 2012 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $5,814 | $43,695 | Not Implemented |
TT0098 # 03 Y:2012 | 03 | 2012 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,898 | $5,525 | Not Implemented |
TT0098 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,222 | $2,320 | Implemented |
TT0098 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,053 | $1,116 | Implemented |
OK0832 # 11 Y:2012 | 11 | 2012 | OPTIMIZE PLANT POWER FACTOR | $1,632 | $8,864 | Not Implemented |
OK0832 # 10 Y:2012 | 10 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,669 | $696 | Not Implemented |
OK0832 # 09 Y:2012 | 09 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,579 | $1,170 | Implemented |
OK0832 # 08 Y:2012 | 08 | 2012 | INSTALL SET-BACK TIMERS | $2,158 | $185 | Not Implemented |
OK0832 # 07 Y:2012 | 07 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,074 | $29,738 | Not Implemented |
OK0832 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,382 | $34,962 | Not Implemented |
OK0832 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,428 | $7,200 | Not Implemented |
OK0832 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $655 | $4,180 | Not Implemented |
OK0832 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $6,375 | Not Implemented |
OK0832 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $955 | $1,288 | Not Implemented |
OK0832 # 01 Y:2012 | 01 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,902 | $7,700 | Not Implemented |
TT0097 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $63,167 | $106,204 | Implemented |
TT0097 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,306 | $19,700 | Not Implemented |
TT0097 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $62,026 | $78,780 | Implemented |
UA0086 # 02 Y:2012 | 02 | 2012 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $7,370 | $1,353 | Implemented |