ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0061 # 04 Y:2011 | 04 | 2011 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $98,700 | $112,800 | Not Implemented |
UA0061 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $164,422 | $19,809 | Not Implemented |
UA0061 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $411,224 | $71,550 | Not Implemented |
DL0068 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,500 | $200 | Implemented |
DL0068 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,200 | $3,200 | Implemented |
DL0068 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $51,300 | $12,000 | Implemented |
DL0068 # 04 Y:2011 | 04 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $182,000 | $17,000 | Not Implemented |
DL0068 # 05 Y:2011 | 05 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $21,659 | $4,300 | Implemented |
DL0068 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $51,400 | $10,000 | Implemented |
DL0068 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,315 | $15,000 | Not Implemented |
DL0068 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $183,000 | $600,000 | Not Implemented |
DL0068 # 09 Y:2011 | 09 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $32,300 | $200 | Implemented |
MS0340 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,689 | $21,753 | Implemented |
MS0340 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,230 | $391 | Implemented |
MS0340 # 03 Y:2009 | 03 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $66 | $510 | Not Implemented |
UA0003 # 01 Y:2007 | 01 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $65,640 | $16,926 | Not Implemented |
UA0003 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,585 | $54,205 | Not Implemented |
UA0003 # 03 Y:2007 | 03 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $43,286 | $20,950 | Not Implemented |
UA0003 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,528 | $0 | Not Implemented |
UA0003 # 05 Y:2007 | 05 | 2007 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,563 | $0 | Not Implemented |
UA0003 # 06 Y:2007 | 06 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,422 | $0 | Not Implemented |
UA0003 # 07 Y:2007 | 07 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $814 | $1,180 | Not Implemented |
UA0003 # 08 Y:2007 | 08 | 2007 | INSTALL OCCUPANCY SENSORS | $166 | $158 | Not Implemented |
UM0309 # 01 Y:2006 | 01 | 2006 | HEAT WATER WITH EXHAUST HEAT | $292,769 | $50,000 | Not Implemented |
UM0309 # 02 Y:2006 | 02 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $32,329 | $10,600 | Not Implemented |